Maintenance and cleaning

Attention! Dangerous electrical voltage

.

Possible consequences: 

Death or serious injuries.

Protective measures:

•  Electrical units and installations with a rated voltage of U > 12 V AC or U >30 V DC located in the water: Isolate the 

units and installations (switch off and disconnect from the power supply) before reaching into the water.

•  Isolate the unit before starting any work.

•  Secure the unit to prevent unintentional switching on.

Cleaning the unit

●   

Regular cleaning of the pump may be necessary depending upon the 

environment in which it is operated. Clean the pump when it is visibly 

soiled or when a drop in performance is detected. Clean the unit with 

warm water using a soft brush.

    

Never use aggressive cleaning agents or chemical solutions. These 

could attack the housing surface or impair the function.

    

In the event of stubborn furring (calcium deposits), a common 

household cleaner free from vinegar and chlorine can be used. 

Subsequently, clean the pump thoroughly using warm water.

Cleaning the pump

1.

   Disconnect the pump from the power source

○ Disconnect the tubing.

2.

   Remove the screen and disassemble the impeller 

housing by unscrewing the screws to expose the 

impeller assembly.  

3.

   Remove the impeller assembly by pulling on the back 

round plate behind the impeller

4. 

  Use a soft cloth or brush to clean the impeller assembly 

and the inside of the impeller housing.

    

Check parts for damages such as cracked shaft, 

cracks in the bearing, and broken plastics. Replace 

parts if necessary.

5.

   Reassemble in the reverse order.

2.

3.

4.

Summary of Contents for 6600

Page 1: ...Waterfall Pump 6600 8000 Operating instructions Notice d emploi Instrucciones de uso...

Page 2: ...ct Waterfall Pump 6600 8000 Prior to operating the unit please read the instructions of use carefully and fully familiarize yourself with the unit Ensure that all work on and with this unit is only ca...

Page 3: ...tion for trouble free operation Intended use Waterfall Pump 6600 8000 referred to in the following as unit may only be used as specified in the following For pumping normal pond water for filters wate...

Page 4: ...3 Attach the other end of the tubing to desired water feature or spillway Submerged installation 1 For maximum water flow it is recommended that the largest tubing size for your pump is used If neede...

Page 5: ...tor has cooled down Risk of accident Install the unit so that it is not exposed to direct sun radiation max 104 F 40 C Important The unit switches on automatically when power connection is established...

Page 6: ...t with warm water using a soft brush Never use aggressive cleaning agents or chemical solutions These could attack the housing surface or impair the function In the event of stubborn furring calcium d...

Page 7: ...Also check to make sure that the ceramic shaft or bearings are not broken Pump is not completely submerged Completely submerge the pump or make sure inline setup is completely below the water line Ins...

Page 8: ...0 ft 1 1 2 2 11 9 x 6 8 x 8 6 in 14 5 lbs 8000 45426 650 W 4 8 A 8 000 GPH 32 ft 20 ft 11 9 x 6 8 x 8 6 in Waterfall Pump Pos Waterfall Pump 6600 8000 1 1 1 2 in and 2 in ID tubing adapter 1 1 2 in an...

Page 9: ...OASE North America INC www oase livingwater com 46631 09 16...

Reviews: