background image

-  English  -

7

Questions, problems, missing parts? 

Before returning to your retailer, call us at 1-866-627-3435, 8 a.m.-6 p.m., EST, Monday-Friday, or email 

us at [email protected].  Or visit our website at www.oase-livingwater.com

Storage/Winterization

●   Put the unit out of operation at water temperatures below 46 °F (8 °C) or, at the latest, when freezing temperatures are 

to be expected.

●   Thoroughly clean the unit, check for damage.
●   Ensure that the storage place is inaccessible to children.

Wear parts

The impeller unit is a wear part and is excluded from the warranty.

Disposal

Do not dispose of this unit with domestic waste! Disable the unit beforehand by cutting off the cables. Further 
information about the recycling of this product can be obtained from your local municipal authority.

Issue

Cause

Solution

The unit is not 

performing its 

suction function

Power supply not connected

Connect pump power supply, check the supply lines to make sure 

the voltage is correct

Impeller blocked, shaft broken

Remove the inlet screen and/or pump cover, and impeller 

housing to expose the impeller. Turn the impeller to ensure that it 

is not broken or jammed by debris. Also check to make sure that 

the ceramic shaft or bearings are not broken.

Pump is not completely 

submerged

Completely submerge the pump or make sure inline setup is 

completely below the water line. 

Insufficient flow

Pump is not completely 

submerged

Completely submerge the pump or make sure inline setup is 

completely below the water line. 

Screen clogged

Clean

Tubing blocked

Clean or replace tubing

Tubing kinked

Eliminate kink, replace tubing if it is damaged

Excessive flow loss in the 

tubing due to friction

○ 

Reduce tubing length to reduce frictional loss

○ 

Select larger hose diameter, adapt stepped hose adapter to 

hose diameter.

Pump overload. The flow is 

automatically stopped to protect 

the pump.

○ 

Clean the pump housing and impeller assembly

○ Reduce the ambient temperature (e.g. ensure that the specified 

water temperature is adhered to, avoid direct sunlight)

Impeller worn

Replace impeller

Unit switches 

off after a short 

running period

Excessive soiled water

Clean impeller housing, bearing and impeller assembly

Impeller blocked, shaft broken

Remove the inlet screen and/or pump cover, and impeller 

housing to expose the impeller. Turn the impeller to ensure that it 

is not broken or jammed by debris. Also check to make sure that 

the ceramic shaft or bearings are not broken.

Water temperature too high

Maximum water temperature: +95° F (+35 °C)

Troubleshooting

Summary of Contents for 6600

Page 1: ...Waterfall Pump 6600 8000 Operating instructions Notice d emploi Instrucciones de uso...

Page 2: ...ct Waterfall Pump 6600 8000 Prior to operating the unit please read the instructions of use carefully and fully familiarize yourself with the unit Ensure that all work on and with this unit is only ca...

Page 3: ...tion for trouble free operation Intended use Waterfall Pump 6600 8000 referred to in the following as unit may only be used as specified in the following For pumping normal pond water for filters wate...

Page 4: ...3 Attach the other end of the tubing to desired water feature or spillway Submerged installation 1 For maximum water flow it is recommended that the largest tubing size for your pump is used If neede...

Page 5: ...tor has cooled down Risk of accident Install the unit so that it is not exposed to direct sun radiation max 104 F 40 C Important The unit switches on automatically when power connection is established...

Page 6: ...t with warm water using a soft brush Never use aggressive cleaning agents or chemical solutions These could attack the housing surface or impair the function In the event of stubborn furring calcium d...

Page 7: ...Also check to make sure that the ceramic shaft or bearings are not broken Pump is not completely submerged Completely submerge the pump or make sure inline setup is completely below the water line Ins...

Page 8: ...0 ft 1 1 2 2 11 9 x 6 8 x 8 6 in 14 5 lbs 8000 45426 650 W 4 8 A 8 000 GPH 32 ft 20 ft 11 9 x 6 8 x 8 6 in Waterfall Pump Pos Waterfall Pump 6600 8000 1 1 1 2 in and 2 in ID tubing adapter 1 1 2 in an...

Page 9: ...OASE North America INC www oase livingwater com 46631 09 16...