background image

Preface 

This instruction manual serves to explain the use of the Temp 4/5/6 temperature 
meter. 

It functions in two ways: first as a step by step guide to help you operate the 
meter; second, it serves as a handy reference guide. 

This manual is written to cover as many anticipated applications of the Temp 
4/5/6 meter as possible. If there are doubts in the use of this meter, please do 
not hesitate to contact the nearest Eutech Instruments/ Oakton Instruments 
Authorized Distributor. 

Eutech Instruments/ Oakton Instruments will not accept any responsibility for 
damage or malfunction to the meter caused by improper use of the instrument.  

The information presented in this manual is subjected to change without notice 
as improvements are made, and does not represent a commitment on the part 
of Eutech Instruments Pte Ltd/ Oakton Instruments. 

 

Copyright © 1999  

Eutech Instruments Pte Ltd/ Oakton Instruments  

Rev. 2   01/03. 

 

Summary of Contents for Temp 4/5/6

Page 1: ...1 Technology Made Easy Instruction Manual Temp 4 5 6 Temperature Meter Series 68X243607 Rev 2 01 03...

Page 2: ...use of this meter please do not hesitate to contact the nearest Eutech Instruments Oakton Instruments Authorized Distributor Eutech Instruments Oakton Instruments will not accept any responsibility fo...

Page 3: ...the Meter On 9 3 CALIBRATION 10 3 1 Temperature Calibration 10 3 1 1 Temperature Calibration using Offset Adjustment 10 3 1 2 Temperature Curve Selection Temp 5 Meter Only 11 4 MEASUREMENT 12 4 1 Tak...

Page 4: ...m hold mode Low battery indicator Hold function freezes measured reading User calibration offset adjustment Built in memory backup calibration and other information remain if battery is disconnected T...

Page 5: ...HOLD ENTER Freezes the measured reading confirm calibration value MAX S UP and MIN T DOWN Momentarily displays meter s maximum and minimum temperature enter maximum or minimum hold mode scroll up and...

Page 6: ...edges of meter until it is completely out of boot Ensure that the connector of temperature sensor is not connected 2 To insert meter into rubber boot slide in from the top of meter before pushing the...

Page 7: ...tery compartment is found at the back of instrument To open the battery compartment push in the direction of arrow and lift up the cover Note the polarity of battery before inserting into position Aft...

Page 8: ...manufacturer Caution Power off the meter when changing battery 2 6 Connecting the Temperature Sensor To connect a temperature probe into the meter align the connector of probe to the meter s socket a...

Page 9: ...r All the LCD segments display momentarily as the meter performs a self diagnostic test per shown in section 2 2 The LCD then switches into measurement mode 2 The LCD displays oPEn if the temperature...

Page 10: ...meter Dip the probe in a constant temperature bath or a liquid whose temperature can be checked with a thermometer known to be accurate For best accuracy place the probe and thermometer in a constant...

Page 11: ...n the measurement mode Press CAL key to enter calibration mode The LCD shows CA and the reading flashes 3 Press o C o F key to enter curve selection mode Press the o C o F key again to scroll through...

Page 12: ...4 2 Displaying Maximum and Minimum Readings The EcoScan Temp meter can momentarily display the maximum and minimum temperature measured since you switched the meter on Simply press MAX S or MIN T key...

Page 13: ...nce entering the Maximum or Minimum Hold mode 1 Power on the meter The meter automatically enters Temperature mode Use o C o F key to switch between Celsius and Fahrenheit reading if desired 2 Press H...

Page 14: ...both the probe and meter into its original packaging when not in use 6 TROUBLESHOOTING Problem Cause Solution Power on but no display a Batteries not in place a Insert batteries b Re insert batteries...

Page 15: ...9 o C 99 9 o F and range 199 9 o C 391 9 o F Accuracy 0 2 o C 0 4 o F 0 2 o C 0 4 o F 99 9 to 199 9 o C 99 9 to 391 9 o F 2 o C 4 o F range 99 9 o C 99 9 o F and range 199 9 o C 391 9 o F Hold Functio...

Page 16: ...00 35626 00 General Purpose Probe 93824 00 Temp 5 Meter with probe EC TEMP5 01 35626 10 100K Thermistor Temperature probe EC TEM5TEM01P 35626 50 Temp 6 Meter with probe EC TEMP6 01 Temp 6 Meter only...

Page 17: ...misuse within the designated period please return freight pre paid and correction will be made without charge Eutech Instruments Oakton Instruments will determine if the product problem is due to dev...

Page 18: ...he reason the items are to be returned For your protection items must be carefully packed to prevent damage in shipment and insured against possible damage or loss Eutech Instruments Oakton Instrument...

Page 19: ...NOTES...

Page 20: ...ruments P O Box 5136 Vernon Hills IL60061 USA Tel in U S 888 462 5866 Tel outside U S 1 847 549 7600 Fax 1 847 247 2984 E mail info 4oakton com www 4oakton com Eutech Instruments Pte Ltd Blk 55 Ayer R...

Reviews: