(the minimum side clearances areautomatically allowed for). Refer to
page 6
f
or top and bottom clearances which can be measured from the template.
Ensure that the template is level and mark hole positions
‘A’.
‘B’, and centre of boiler reference line through the slot in the bottom edge of th
e template.
If the flue is to rise through the ceiling, mark out centre line of hole for flue by
extending the dotted line on template vertically and measure out 160mm from
rear wall asillustrated.
FIG. 8 BOILER MOUNTING PLATE
Remove template and drill holes
‘A’ using a 7mm drill.
Drill holes
‘B’ using a 5mm drill and insert the wall plugs from accessory pack
B into the holes.
Cut hole through wall or ceiling as necessary for intended run of flue pipe.
Using wall plugs, screws and washers (accessory pack A) attach boiler mounti
ng plate to wall ensuring it is level.
Remove the adjustment screws from the polythene bag in the boiler carton an
d screw them into the boiler legs as illustrated in
FIG. 9.
Page 12