The response to the
NXP_FELICA_RAW
command is as follows:
Table 95.
FeliCa
Raw Response parameters
Description Length
Status 1
Data N
•
Status: bits b0 to b2 indicate information on valid bits in the last data byte (value 0
indicates all are valid, from 1 to 7 it indicated the number of valid bits.
•
Data is the raw frame received from the card.
Note: As FeliCa operates with full bytes, Status byte of NXP_FELICA_RAW command
value should be 0x00.
Table 96.
NXP_FELICA_CMD Command
Value Command
Description
’21’
NXP_FELICA_CMD
This command allows the exchange of data between the
host and a FeliCa card previously activated.
This command has the following parameters:
Table 97.
NXP_FELICA_CMD Parameters
Description Length
Cmd 1
Data N
•
Cmd describe the FeliCa
command type
Table 98.
FeliCa Command Description
Value Description
0x00 Check
0x01 Update
others RFU
•
Data is an array containing the data to be sent within the command as follows:
−
Check command: