Nu-Link-Gang
Dec. 23, 2019
Page
23
of 37
Rev 1.00
NU
-LINK
-GA
NG
USE
R MA
NU
AL
Figure 4-7 IC Mode in Mode 2
4.7
Start Programming
4.7.1 Programming
Plug-in a 9V/1A power adapter to the Nu-Link-Gang and press the Power button once as Figure 4-8,
and press the Reset button on the Nuvoton NUC505 ICP Gang Adapter.
Press the Start ALL button or the individual Start button depends on the programming mode switch
setting to start the programming process. The status LEDs on the Nu-Link-Gang and the Nuvoton
NUC505 ICP Gang Adapter will show the programming results of every unit. Change the target chip in
the adapter, and repeat section 4.6 process.
Figure 4-8 Nu-Link-Gang Power On
4.7.2 LCD Display
LCD display shows four units programming status includes programming times and programming
voltage as Figure 4-9. The LCD control buttons function please refer to section 3.5.2.