MANUFACTURER :  

 

NÜVE SANAYİ MALZEMELERİ                                
İMALAT VE TİCARET A.Ş. 

 

 

         

Saracalar Mah

. Saracalar Kümeevleri No: 4/2  

Akyurt 06750 Ankara-TURKEY 

 

 

TEL:  +(90)  312 399 28 30 (pbx)   

 

 

 

FAX:  +(90) 312 399 21 97   

 

 

 

 

E-mail: [email protected]   

 

 

 

 

 

 

 

 

 

 

 

              

 

 

WARRANTY CERTIFICATE 

 
1. 

Nüve  warrants  that  the  equipment  delivered  is  free  from  defects  during  material  and 
workmanship.  This  warranty  is  provided  for  a  period  of  two  years.  The  warranty  period 
begins from the delivery date. 

 
2. 

Warranty  does  not  apply  to  parts  normally  consumed  during  operation  or  general 
maintenance  or  any  adjustments  described  in  the  operating  instructions  provided  with  the 
equipment. 

 

3. 

Nüve does not accept any liability in the case where the goods are not used in accordance 
with their proper intent. 

 

4. 

The warranty may not be claimed for damages occurred during the shipment, for damages 
resulting  from  improper  handling  or  use,  the  defects  in  maintenance,  negligence,  bad 
functioning  of  auxiliary  equipment,  in  the  case  of  force  majeure  or  accident  and  incorrect 
power supply. 

 

5. 

In the event of failure, Nüve shall be under no liability for any injury, or any loss or damage 
as the result of the failure other than the guarantee conditions. 

 

 

BEFORE  OPERATING  THE  INSTRUMENT  THIS  MANUAL  SHOULD  BE  READ 
CAREFULLY. 

 

 

THE  VALIDITY  OF  THE  GUARANTEE  IS  SUBJECT  TO  THE  OBSERVATION  OF  THE 
INSTRUCTIONS AND PRECAUTIONS DESCRIBED IN THIS MANUAL. 

 

 

INFORMATION CONTAINED IN THIS DOCUMENT IS THE PROPERTY OF NÜVE. IT MAY 
NOT BE DUPLICATED OR DISTRIBUTED WITHOUT PERMISSION. 
 

 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for NF 048

Page 1: ...0 N VE SANAY MALZEMELER MALAT VE T CARET A NF 048 BENCH TOP CENTRIFUGE USER S MANUAL Z14 K 25 225 Rev No 06 Rev Date 01 2016...

Page 2: ...lity in the case where the goods are not used in accordance with their proper intent 4 The warranty may not be claimed for damages occurred during the shipment for damages resulting from improper hand...

Page 3: ...ove the warning labels do not operate damaged instrument do not operate the instrument with a damaged cable do not move the instrument during operation In case of a problem contact your N ve agent for...

Page 4: ...PORT 7 4 2 UNPACKING 7 4 3 POSITIONING 8 4 4 MAINS SUPPLY 8 SECTION 5 OPERATING PRINCIPLES 9 5 1 CONTROL PANEL 9 SECTION 6 OPERATING PRINCIPLES 10 6 1 LOADING 10 6 2 PROGRAMMING 11 6 3 MANUAL LID OPEN...

Page 5: ...e microprocessor control system speed RPM or RCF and time could be programmed and the pulse function provides the operator to run the programs of short duration It ensures safe processes by means of t...

Page 6: ...tep 10 rpm Timer set range 1 99 minutes and hold position Timer set step 1 minute Motor Induction Motor Supply Values 230 V 50 60 Hz Power Consumption 450 W External Dim s WXDXH mm 275x355x240 Packing...

Page 7: ...anyone and any hazardous materials should not be in the 300 mm safety zone while centrifuge is running Do not move the device while it is running Do not open the lid while rotor is spinning Apply the...

Page 8: ...the rotor and motor shaft SECTION 3 SYMBOLS Symbol in the operating instructions Attention general hazard area This symbol refers to safety relevant warnings and indicates possibly dangerous situation...

Page 9: ...should not be in the 300 mm security area ATTENTION The centrifuges are designed to operate safely under the following conditions Indoor use only Ambient temperature 5 C to 25 C Maximum relative humid...

Page 10: ...also shown on this display 02 Time Display This display shows the time during programming and the run 03 Lid Key and Led This key opens the lid if the led is on It is active before starting the centri...

Page 11: ...ht as the one diametrically opposite for balancing In case the number of tubes which will be centrifuged is less than the capacity of the rotor the tubes must be placed in opposite inserts If the numb...

Page 12: ...kapa anahtar yla bekleme konumuna getirdikten sonra ve yapt n z her program n al mas bittikten sonra yeni bir program al t rmak i in kapa a p kapaman z gerekmektedir 6 3 MANUAL LID OPENING In case of...

Page 13: ...or tube breakage the chamber should be cleaned well Take necessary precautions while cleaning the chamber after tube breakage There could be glass particles in the chamber which may cut the hands Roto...

Page 14: ...entially infectious Before doing any servicing on the instrument it is very important to thoroughly disinfect all possibly contaminated parts Before the instrument is removed from the laboratory for d...

Page 15: ...tor overheat failure Please wait for the motor to cool down and start the centrifuge again Err 6 Motor driver PCB is defective Lid open This failure occurs when lid is opened during the centrifugation...

Page 16: ...15 SECTION 10 ELECTRICAL CIRCUIT DIAGRAM 10 1 NF 048 ELECTRICAL CIRCUIT DIAGRAM...

Page 17: ...16 SECTION 11 WARNING LABEL GROUNDED PLUG...