![Nuvair Coltri MCH 36 Electric User Manual Download Page 25](http://html1.mh-extra.com/html/nuvair/coltri-mch-36-electric/coltri-mch-36-electric_user-manual_1719773025.webp)
MCH36 Open Diesel (Kubota)
www.nuvair.com Page | 23
MCH36 Open Diesel (Kubota)
Use only the specified Nuvair lubricants in this system. The use of incompatible lubricants
presents a risk of fire and/or explosion, and may result in system damage. This can lead to
severe personal injury and death.
Do not carry out these tasks if the compressor has only just shut down; wait for the
compressor to cool. Pressure must be drained before opening LP Fill Plug.
Any oil spilt during the oil/filter change could cause personnel to slip; wear protective
garments and anti-slip footwear and remove traces of oil immediately.
Both oil and filter are classified as special wastes and must therefore be disposed of in
compliance with the anti-pollution laws in force.
All maintenance work must be carried out with the compressor OFF and the key removed
from the ignition.
The compressor must be placed on a solid surface with a tilt of no more than 6°.
11.7 Checking the Oil Level
The oil level must be checked every 5 working
hours of the compressor.
The oil level must be between the minimum and
the maximum shown on the oil level indicator.
(See close-up picture bottom of next page)
If the oil level is above the maximum level:
•
Position a recipient under the drain hose so
that the oil flows into the exhausted oil
recipient.
•
Open the drain valve and let the oil flow out
until the oil level returns within the max. and
min. limits
•
Close the drain valve.
If the oil level is below the minimum level:
•
Open the top fill plug
•
Top off with oil until the level returns within the max. and min. limits
•
Close the fill plug.
After running the compressor, the lubricant will be very hot. Take care when removing the
drain plug and draining the lubricant to avoid burns.
Lubricant
Fill Plug
Oil Level
Indicator
Oil drain
valve