MCH36 Open Diesel (Kubota)
www.nuvair.com Page | 16
MCH36 Open Diesel (Kubota)
6.0
Compressor Specifications
Ambient room temperature should never exceed 113
o
F (45
o
C) during operation of the
Compressor System. Operation at higher temperatures may lead to system damage and
malfunction.
6.1 Unpack and Installation
1. Please read all information supplied before physically installing the Compressor System.
2. Unpack the system and remove from the pallet. Visually inspect the system to make
sure there has been no damage during shipping. If damaged, please call Nuvair to file a
damage report. Please take photos and supply detailed information about the damage.
3. Place the system in a permanent location allowing a minimum spacing of 36” from
adjacent walls. Select a location where ambient room temperature is a minimum of 41°F
to a maximum 113°F (°C Min. 5° - Max. 45°).
4. Make sure the installation space is well ventilated.
MCH 36 Kubota
SCFM
Filling a tank 80 cu ft. tank from 500PSI
26.4 SCFM, 748 L/Min
FAD
22FAD , 623 L/Min
Kubota Diesel Engine
37hp (28kW)
Max Operating Pressure
6000 PSI (413 Bar)
RPM
1300
Number of Stages
4
Lubrication
5 Quarts (4.5 liters)
Oil Pressure
5.8 psi (.4-4 bar)
Air Quality
Grade E
Dimensions (WxDxH)
64in x 44in x 42in (163cm x 112cm x 107cm)
Weight
1600 lbs (726 kg)