MCH36 Open Diesel (Kubota)
www.nuvair.com Page | 18
MCH36 Open Diesel (Kubota)
8.0
Control Panel
8.1
1
st
stage pressure gauge
(1)
The
(1)
gauge indicates the pressure inside the 1
st
compression stage. If the Pressure is not
between 45 PSI (3 bar) and 60 PSI (4 bar) switch off the compressor and contact Nuvair.
8.2
2
nd
stage pressure gauge
(2)
The
(2)
gauge indicates the pressure inside the 1
st
compression stage. If the Pressure is not
between 230 PSI (16 bar) and 290 PSI (20 bar) switch off the compressor and contact
Nuvair.
8.3
3
rd
stage pressure gauge
(3)
The
(3)
gauge indicates the pressure inside the 1
st
compression stage. If the Pressure is not
between 940 PSI (65 bar) and 1200 PSI (80 bar) switch off the compressor and contact
Nuvair.
8.4
4
th
stage pressure gauge / Working Pressure Gauge
(4)
This
(4)
gauge indicates the pressure as it exits the compressor. If the Pressure fails to reach
the pressure set on the pressure switch, switch off the compressor and contact Nuvair.
8.5
Oil Pressure Gauge
-
If No Oil Pressure or High Pressure readings occur, switch off compressor and contact
Nuvair.
8.6
Fill Pressure Gauge
- Pressure at the fill whips.
9.0
Safety Valve Checks
Check that safety valves are working properly by starting the compressor with the end taps
closed: this will raise circuit pressure fast and trip the valves when their pressure setting is
reached. The valves are pre-adjusted to 3200 psi (225 bar), 4300 psi (300 bar), 4700 psi
(330 bar) or 6000 psi (425 bar).
Oil Pressure
5.8 to 58 psi
(.4 to 4 bar)