background image

1

OPTION

 - To mount housing anywhere between ceiling framing: 

Use optional Hanger Bar Kit (sold separately from local distributors or 
website). Follow mounting instructions included with kit.

ROOF CAP* (with built-in damper)

WALL CAP*
(with built-in

damper)

4-IN. ROUND

ELBOWS*

FAN

HOUSING

Seal gaps

around

housing.

Seal duct joints

with tape.

INSULATION

(Place around and

over fan housing.)

POWER

CABLE *

* Purchase separately.

OR

Keep duct

runs short.

4-IN. ROUND

DUCT*

IMPORTANT

 - The ducting from this fan to the outside of the building 

has a strong effect on the air fl ow, noise and energy use of the fan. Use the 
shortest, straightest duct routing possible for best performance, and avoid 
installing the fan with smaller ducts than recommended. Insulation around 
the ducts can reduce energy loss and inhibit mold growth. Fans installed 
with existing ducts may not achieve their rated airfl ow.

 

 

WARNING  

  

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, 
OBSERVE THE FOLLOWING:

1.  Use this unit only in the manner intended by the manufacturer. If you have questions, 

contact the manufacturer at the address or telephone number listed in the warranty.

2.  Before servicing or cleaning unit, switch power off at service panel and lock the 

service disconnecting means to prevent power from being switched on accidentally. 
When the service disconnecting means cannot be locked, securely fasten a 
prominent warning device, such as a tag, to the service panel.

3.  Installation work and electrical wiring must be done by a qualifi ed person(s) in 

accordance with all applicable codes and standards, including fi re-rated construction 
codes and standards.

4. Suffi cient air is needed for proper combustion and exhausting of gases through 

the fl ue (chimney) of fuel burning equipment to prevent backdrafting. Follow the 
heating equipment manufacturer’s guideline and safety standards such as those 
published by the National Fire Protection Association (NFPA), and the American 
Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and 
the local code authorities.

5.  When cutting or drilling into wall or ceiling, do not damage electrical wiring and 

other hidden utilities.

6.  Ducted fans must always be vented to the outdoors.

7.  Acceptable for use over a tub or shower when connected to a GFCI (Ground Fault 

Circuit Interrupter) - protected branch circuit (ceiling installation only).

8.  This unit must be grounded.

9.  If you’ve never installed electrical appliances that require wiring, you may need 

assistance from someone with more experience.

 

CAUTION

  

1.  For general ventilating use only. Do not use to exhaust hazardous or explosive 

materials and vapors.

2.  This product can be installed in a wall if mounted 8-ft. or more above the fl oor.

3.  To avoid motor bearing damage and noisy and/or unbalanced impellers, keep 

drywall spray, construction dust, etc. off power unit.

4.  Please read specifi cation label on product for further information and requirements.

READ AND SAVE THESE INSTRUCTIONS

Cooking

Equipment

Floor

COOKING AREA

Do not install above or

inside this area.

45

o

45

o

NOT FOR USE IN

A COOKING AREA.

CLEANING & MAINTENANCE

For quiet and effi cient operation, long life, and attractive appearance - lower
or remove grille and vacuum interior of unit with the dusting brush attachment.

The motor is permanently lubricated and never needs oiling. If the motor 
bearings are making excessive or unusual noises, replace the blower 
assembly (includes motor and impeller).

OPERATION

The Voice Controlled Fan/Light/Speaker must be operated using only the 
wall control included. See separate operating instructions. DO NOT operate 
the Voice Controlled Fan/Light/Speaker with any other switches or controls.

For Warranty Statement, Service Parts, Technical Support, or to 
Register your product, please visit our website or call:
In the United States - broan-nutone.com  800-558-1711.
In Canada - broan-nutone.ca   800-567-3855

SENSONIC VOICE™ Voice Control

Fan/Light/Speaker Installation Instructions

The 

Bluetooth

®

 word mark and logos are registered trademarks owned by 

Bluetooth

®

 SIG, Inc. 

and any use of such marks by Broan-NuTone LLC is under license. Other trademark and trade 
names are those of their respective owners. The APPLE logo and APP STORE are trademarks of 
Apple Inc., registered in the United States and other countries and regions. App store is a service 
mark of Apple Inc. Google Play and the Google Play logo are trademarks of Google LLC. Amazon, 
Alexa and all related logos are trademarks of Amazon.com, Inc. or its affi liates.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital 
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable 
protection against harmful interference in a residential installation. This equipment generates, 
uses and can radiate radio frequency energy and, if not installed and used in accordance with 
the instructions, may cause harmful interference to radio communications. However, there is no 
guarantee that interference will not occur in a particular installation. If this equipment does cause 
harmful interference to radio or television reception, which can be determined by turning the 
equipment off and on, the user is encouraged to try to correct the interference by one or more 
of the following measures:
•  Reorient or relocate the receiving antenna.
•  Increase the separation between the equipment and receiver.
•  Connect the equipment into an outlet on a circuit different from that to which the receiver is 

connected.

•  Consult the dealer or an experienced radio/TV technician for help.
This device complies with Part 15 of the FCC Rules and RSS-210 of Canada. Operation is subject 
to the following two conditions:
(1) This device may not cause interference, and (2) this device must accept any interference 
received, including interference that may cause undesired operation.    FCC IDs: 2ADLL-1108935 
& 2ADLL-1109038     IC : 2143B-1108935 & 2143B-1109038 

  

This 

Bluetooth

®

 wireless technology enabled luminaire complies with FCC radiation exposure 

limits set forth for an uncontrolled environment. End users must follow the specifi c operating 
instructions for satisfying exposure compliance. This luminaire must not be co-located or 
operate in conjunction with any other antenna or transmitter.
Changes or modifi cations not expressly approved by the party responsible for compliance could 
void the user’s authority to operate the equipment.

Summary of Contents for SENSONIC VOICE VC110CCT

Page 1: ...TENANCE For quiet and ef cient operation long life and attractive appearance lower orremovegrilleandvacuuminteriorofunitwiththedustingbrushattachment The motor is permanently lubricated and never need...

Page 2: ...through mounting ears with appropriate fasteners If mounting housing to I joist use wood blocking as shown NEW INSTALLATION 1 5 HOUSING TABS I JOIST WOOD BLOCKING 1 3 A pair of flanges may be attached...

Page 3: ...essary to 9 parallel to joist by 10 perpendicular to joist Some models have a cut out template on side of carton Connect 4 in round duct Pull existing ducting through housing discharge opening and tap...

Page 4: ...to new single gang electrical box Recommended method 2 Mount control to wall with clearance hole in wall Remove control module install 2 AAA batteries and replace module Snap control cover in place N...

Page 5: ...OICEMC avec clairage et haut parleur La d signation et les logos BluetoothMD sont des marques d pos es appartenant BluetoothMD SIG Inc et sont utilis s sous licence par Broan NuTone LLC Tous les autre...

Page 6: ...tions appropri es Si vous xez le bo tier une solive en I utilisez un bloc de bois comme illustr NOUVELLE INSTALLATION 1 5 ERGOTS DU BO TIER SOLIVE EN I BLOC DE BOIS 1 3 Il est possible de fixer une pa...

Page 7: ...10 cm 4 po Tirez le conduit existant par la sortie et xez le au raccord avec du ruban conduit Repoussez le raccord conduit au travers de l ouverture Engagez les ergots et xez le tout avec la vis se tr...

Page 8: ...ctrique simple M thode recommand e 2 Montez la commande au mur avec un trou de passage dans le mur Retirez le module de la commande installez 2 piles AAA et replacez le module Embo tez le couvercle de...

Reviews: