background image

2

1

1

ALL INSTALLATIONS

Remove all packing material, unplug 
and remove blower from fan housing.

Remove wiring panel 
from fan housing (if 
already installed).

1

2

For Retrofi t Installation -

Skip to Page 3. 

1

4

Attach damper/duct connector to
fan housing.

Mount housing to ceiling structure.

TABS

Push connector 
through opening 
from inside of 
housing.

Engage tabs 
and secure with 
screw from parts 
bag.

Make sure bottom of housing will 
be fl ush with fi nished ceiling.

For proper location using 1/2” 
ceiling material: Bend out housing 
tabs (on outside of housing) to fi t 
against bottom of joist.

Secure housing through mounting 
ears with appropriate fasteners. If 
mounting housing to I-joist, use 
wood blocking as shown.

NEW INSTALLATION

1

5

HOUSING TABS

I-JOIST

WOOD
BLOCKING

1

3

A pair of fl anges 
may be attached to 
housing if desired or 
required.

Snap both fl ange pieces under 
rolled-over edge of housing (all four 
sides).

1

1

6

7

Connect 4-in. 
round duct.

Connect wiring.

Finish ceiling.

Then continue with Step 9.

Connect power cable 
that will supply constant 
120V AC to unit. Attach 
wiring to wiring plate 
(from parts bag) using 
UL approved connector. 
Connect house wiring to 
fan wiring - black to black, 
white to white, and green 
to green or bare wire. Use 
screw (from parts bag) 
to secure wiring plate to fan housing. Re-install 
wiring panel and secure with screw from parts bag. 
See wiring diagram on page 4.

1

8

Summary of Contents for SENSONIC VOICE VC110CCT

Page 1: ...TENANCE For quiet and ef cient operation long life and attractive appearance lower orremovegrilleandvacuuminteriorofunitwiththedustingbrushattachment The motor is permanently lubricated and never need...

Page 2: ...through mounting ears with appropriate fasteners If mounting housing to I joist use wood blocking as shown NEW INSTALLATION 1 5 HOUSING TABS I JOIST WOOD BLOCKING 1 3 A pair of flanges may be attached...

Page 3: ...essary to 9 parallel to joist by 10 perpendicular to joist Some models have a cut out template on side of carton Connect 4 in round duct Pull existing ducting through housing discharge opening and tap...

Page 4: ...to new single gang electrical box Recommended method 2 Mount control to wall with clearance hole in wall Remove control module install 2 AAA batteries and replace module Snap control cover in place N...

Page 5: ...OICEMC avec clairage et haut parleur La d signation et les logos BluetoothMD sont des marques d pos es appartenant BluetoothMD SIG Inc et sont utilis s sous licence par Broan NuTone LLC Tous les autre...

Page 6: ...tions appropri es Si vous xez le bo tier une solive en I utilisez un bloc de bois comme illustr NOUVELLE INSTALLATION 1 5 ERGOTS DU BO TIER SOLIVE EN I BLOC DE BOIS 1 3 Il est possible de fixer une pa...

Page 7: ...10 cm 4 po Tirez le conduit existant par la sortie et xez le au raccord avec du ruban conduit Repoussez le raccord conduit au travers de l ouverture Engagez les ergots et xez le tout avec la vis se tr...

Page 8: ...ctrique simple M thode recommand e 2 Montez la commande au mur avec un trou de passage dans le mur Retirez le module de la commande installez 2 piles AAA et replacez le module Embo tez le couvercle de...