9.1
RESIN AND
SOFTENER
REGENERATION
To avoid scaling deposits in the boiler and in
the heating exchangers, the softener must
always be kept efficient. Therefore, the ionic
resins must be regularly regenerated.
Regeneration times are established according
to the quantity of coffee delivered daily and
the hardness of the water utilised.
As an indication, regeneration times can be
calculated on the basis diagram illustrated in
Fig. 31.
Fig. 31
9.
MAINTENANCE
NOTE: During maintenance/repairs, the parts
used must be able to guarantee compli-
ance with the safety and hygiene
requirements envisaged for the device.
Original replacement parts can offer
this guarantee.
NOTE: After the repair or replacement of any
components of parts that come into
contact with food or water, it is neces-
sary to carry out the washing procedure
as described in point 1.4 or according
to the manufacturer’s instructions.
C
E
D
G
C
D
C
F
D
Regeneration procedures are as follows:
1) Turn the machine off and place a container
large enough to contain at least 5 litres
under tube E (Fig. 32).
Turn levers C and D from left to right; take
the cap off by unscrewing knob and fill with
1 Kg normal kitchen salt (Fig. 33).
2) Put the cap back on and reposition lever C
moving it towards the left (Fig. 34) and
allowing tube F to discharge the salty water
until it has been eliminated and the water
becomes fresh again (about half and hour).
3) Reposition lever D towards the left (Fig. 35).