60
ENGLISH
• Use the
keys to set both
values.
• Use the
key to confirm.
Once the set delivery limit or the set main-
tenance date have been reached, the dis-
play will visualize the message:
MAINTENANCE PROGRAMMING
• The display will read:
• By pressing the
key, the display will
read:
MAINTENANCE
MAINTENANCE
DELIVE. 10000
01 GENNUARY 2005
SETTING THE SET POINT PRESS:
The SET POIN POINT allows to chose the pres-
sure/ temperature in the working status.
When the
key is pressed, the display
will read:
If the delivery time display is on when a
delivery is started - unless with the
Continuous function - the bottom line of the
display will show the delivery time (or times
if more than one unit is delivering).
Each group has an area of the bottom line:
the area on the left is for unit 1; the area
alongside it is for unit 2 and so on, until the
area on the far right, which is for unit 4.
The different areas are separated by vertical
bars; if a group is not delivering, the area is
empty.
Here below is an example: unit 1 is deliver-
ing (it has just started and 0 seconds have
passed); unit 2 has been delivering for 12
seconds and unit 4 is delivering (it has been
delivering for 21 seconds).
SETPOINT PRESS
PRESSURE - TEMPERATURE TABLE
AURELIA Digit
Bar
°C
°F
0,50
110,5
230,9
0,55
111,5
232,7
0,60
112,5
234,5
0,65
113,5
236,3
0,70
114
237,2
0,75
115
239
0,80
115,5
239,9
0,85
116,5
241,7
0,90
117,5
243,5
0,95
118
244,4
1,00
119
246,2
1,05
119,5
247,1
1,10
120,5
248,9
1,15
121
249,8
1,20
122
251,6
1,25
112,5
252,5
1,30
123
253,4
1,35
124
255,2
1,40
124,5
256,1
1,45
125
257
1,50
126
258,8
1,55
126,5
1,60
127
HISTORICAL ALARM
VISUALISATION
• The display will read:
• By pressing the
key, the display
will read:
• Pressing the
key, allows you to
scroll down the ten previous alarms saved in
the memory. After the tenth alarm, by press-
ing the
key again you can go on to
the next page.
FAULTS HISTORY
ERROR 01
SETPOINT PRESS
XX.XX BAR
THURSDAY
12:00
0 I 12 I I 21
Area reserved to the
delivery time of unit 1
Area reserved to the
delivery time of unit 4
Area reserved to the
delivery time of unit 2
Area reserved to the
delivery time of unit 3
Press
to adjust the work-
press/temp point.
• Press
to confirm and pass to the
next step.
• Press
to return to the previous page
without confirming.
Summary of Contents for Aurelia
Page 1: ...LIBRETTO ISTRUZIONI USER HANDBOOK ...
Page 2: ......
Page 6: ...4 ITALIANO ...
Page 42: ...ENGLISH 40 ...
Page 79: ...NOTE NOTES ...
Page 80: ...NOTE NOTES ...
Page 81: ......