DSP
LASER
DSPLSR01EN
9
PMS
= Top Dead Centre: highest point of the stroke generally set by the numeric
control, to achieve the wished bend.
PCV
= Speed Change Point: point of the closing stroke where the change from
fast approaching speed to working speed, lower than or equal to 10
mm/sec, takes place.
PMI
= Bottom Dead Centre: lowest point of the stroke of the mobile cross-bar
generally set by the numeric control, to achieve the wished bend.
8.
Planning safety measures
The device DSP LASER has been designed following the indications provided by the rules:
CEI EN 61496-1:2014 and CEI EN 61496-2:2014, it can be classified as ESPE of type 4.
ISO 13849-1:2015, it can be classified as PL=e; SIL3.
The laser contained in DSP LASER is classified as CLASS 1M according to the rule CEI EN
60825-1:2015.
DSP LASER, if correctly installed and used as described in this Manual, is in compliance
with the prescriptions of:
•
Machinery Directive 2006/42/CE and relevant rules and reference specifications:
o
CEI EN 61496-1:2014 and CEI EN 61496-2:2015
o
UNI EN 12100:2010,
EN 12622:2014, CEI EN 60204-1:2006, CEI EN 60825-1:2015
•
Low Voltage Directive 2014/35/UE and relevant reference rules
o
CEI EN 61496-1:2014
o
CEI EN 60204-1:2006
•
Electromagnetic Compatibility Directive 2014/30/UE and relevant reference rules
o
CEI EN 61496-1:2014
o
CEI EN 61000-6-3 :2007 + A1:2011 e IEC 61000-6-2 :2016
•
The transformer has been designed in compliance with the rule CEI EN 61558-
1:2006.
Summary of Contents for DSP LASER
Page 2: ......
Page 4: ......
Page 48: ...DSP LASER 44 DSPLSR01EN CONNECTION SCHEMES Fig 13 6 scheme of connection with AL1B...
Page 49: ...DSP LASER DSPLSR01EN 45 Fig 13 7 scheme of connection with AL2B...
Page 50: ...DSP LASER 46 DSPLSR01EN Fig 13 8 scheme of connection with ALdc...
Page 51: ...DSP LASER DSPLSR01EN 47 Fig 13 9 scheme of connection without AL module...