3.5 Remote Sensor

DRI-365 units are supplied with 15 metres of 2 core cable pre-wired and 
ready to connect to the Remote Sensor.

The Remote Sensor is used in conjunction with the units internal sensor 
to allow the system to operate in “Heat Recovery Mode”.

The sensor is fitted with an LED indicator which is capable of providing 
various status information if required:

FLASHING RED  - 

after 5 years from commissioning to indicate 

that the filters need cleaning or replacement.

PERMANENT RED - 

to indicate a failure.

GREEN - 

to indicate when the system is in ‘Heat Recovery Mode’.

AMBER - 

which indicates normal operation.

If it is desired to disable the LED function completely the LED itself may 
be ‘bent’ over to one side in order to render it ‘blind’ to the user.

Remote Sensor

 

 

DRImaster

NUAIRE

3.5.1 Remote Sensor Installation

For good EMC engineering practice, power supply output cables 
and any sensor cables should not be placed within 50mm of other 
cables or each other.

The Remote Temperature Sensor incorporates a clip-in fixing bracket 
which can be removed for easy fitting to a suitable surface.

Select a suitable location for the sensor e.g. close to ceiling height 
in a bedroom or hallway BUT NOT WITHIN 3 METRES of the 
diffuser.

Arrange the connecting cable in position. Leave approx. 75mm of 
the cable free at the mounting point to ease the connection of the 
cable.

Carefully separate the sensor from the fixing bracket using a small 
screwdriver.

Fix the bracket to the wall and arrange the end of the cable to fall 
through the slot cut in the bracket.

Carefully separate the two sensor halves to reveal the wiring 
connection terminals.

Feed the twin cable through the cut out rear half and connect the 
two wires to the terminals.

Reassemble the sensor body halves.

Clip the sensor body in the fixing bracket arms and adjust the 
sensor body to the desired position.

The remote sensor is connected to the circuit board via the supplied 
2 core cable and into the connector labelled ‘Remote Sensor’ on the 
circuit board.

Remote Sensor Installation

Connector
Block

15m sensor
connection
wire 
(pre-wired
to unit).

Allow approx 
75mm of wire 
through for 
fitting to the 
backplate.

Wire can be 
located behind 
a wall panel or 
fixed to wall 
surface.

LED

Bracket Fixing Screws

Summary of Contents for DRI-365

Page 1: ...le guards This appliance should not be used by children or persons with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or i...

Page 2: ...ery mode The unit will increase in speed and supply more air to the property The unit can be boosted to obtain maximum ventilation by the operation of a boost switch 3 0 MECHANICAL INSTALLATION Succes...

Page 3: ...d correctly in the central hallway in single storey properties or in the ceiling of the top floor landing on 2 or more storey dwellings The diffuser discharges air evenly in all directions along the u...

Page 4: ...on soffit inlets FLDI150 5m length of 150mm dia insulated ducting RDC150 150mm duct connector for connecting 222 x 90 flexible duct to 150mm duct 777483 2m length insulated flexible ducting DT33 Qty...

Page 5: ...The Remote Temperature Sensor incorporates a clip in fixing bracket which can be removed for easy fitting to a suitable surface Select a suitable location for the sensor e g close to ceiling height in...

Page 6: ...house Switch supplied Speed 6 sensor supplied indicator lights 5 0 CONTROLS 5 1 Fan Speed Adjustment The unit has 6 air volume speed settings The setting switch is located on the rear of the fan case...

Page 7: ...dance with the details contained in this manual and general good practice The product warranty applies to the UK mainland and in accordance with Clause 14 of our Conditions of Sale Customers purchasin...

Page 8: ...8 20 05 21 Document Number 671771 Nuaire Western Industrial Estate Caerphilly CF83 1NA nuaire co uk DRI 365 Installation Manual NOTES...

Reviews: