DRI-365
Installation Manual
3.3 Fan Unit Installation
3.3.1 Mounting Fan Unit (Standard Configuration)
Connect the two ‘L’ shape fixing brackets to the long sides of the unit
with the M5 screws (provided) then lower the unit with the “L” shape
fixing brackets attached to the unit onto the joists. Mark 4 holes
through the brackets so that the holes will be centrally positioned over
a joist.
Locate anti-vibration mounts (supplied) above and below each bracket
fixing joint hole and, using 4 suitable screws (not provided) and
washers, fix the unit to the joists.
Do not over-tighten the fixings.
3
Standard Fan Unit Mounting
Connect fixing brackets
to unit with the 4 M5
screws provided.
Connect 2 ‘L’ shape
fixing brackets and
the AV mounts to
roof joists with
4 suitable screws.
AV mount
Connect fixing brackets
to the unit with the
4 M5 screws provided.
4
Anti-Vibration Mount Installation
Fixing
Bracket
A.V.
Mount
3” Woodscrew
Washer
A.V.
Mount
12mm
Clearance
Hole
3.3.2 Mounting Fan Unit (Optional Configuration)
Using a similar procedure the two ‘L’ shape fixing brackets can also
be mounted on the short sides of the DRI-365 unit if an alternative
mounting position is required.
5
Optional Fan Unit Mounting
AV mounts.
Connect 2 ‘L’ shape
fixing brackets and
the 4 AV mounts
to roof joists with
4 suitable screws.
Connect fixing brackets
to ends of unit with
4 M5 screws provided.
3.2 Ceiling Diffuser Installation
3.2.1 Ceiling Diffuser Location
The diffuser has a unique air throw pattern and it is essential that it is
located correctly in the central hallway in single storey properties or in
the ceiling of the top floor landing on 2 or more storey dwellings. The
diffuser discharges air evenly in all directions along the underside of the
ceiling.
SMOKE ALARMS -It is also important to ensure that the diffuser is
NOT placed within 1 metre of a smoke alarm.
Where a floor/room is more than 4.5m tall, the fan unit must be
fitted with a 3 storey aluminium diffuser and requirements in
section 5.2 followed.
If the diffuser cannot be repositioned, two sides of the diffuser must
be closed off using the air dams supplied to encourage the air through
the remaining open sides that faces at least 1.5 metres of unobstructed
area away from the smoke alarm sensor.
Speed Setting
Minimum Distance Between Diffuser & Wall
1
100mm
2
155mm
3
400mm
4
625mm
5
850mm
6
1000mm
3.2.2 Directing Airflow
Air dams should be fitted as needed, to alter the direction of airflow
required. Two air dams are supplied and will fit on any of the diffuser
sides to guide airflow away from a smoke detector and/or obstructions.
Ceiling Vent
Two Air Dams
Diffuser Cap
Airflow
Airflow
1
Ceiling Diffuser Overview
3.2.3 Mounting Ceiling Diffuser
To install the diffuser, use the tear-out template from the lid of the unit
packaging and trace the shape onto the ceiling between two convenient
joists. Once the shape has been cut out, position the ceiling vent by
aligning the label on the ceiling vent with the narrowest point of the
ellipse and secure it in place using the 4 screws and plugs provided.
Finally attach the diffuser cap to the frame using the four built-in press
on clips provided.
2
Fan Unit Overview
150mm dia.
200mm dia.
Flexible Ducting
Air from loft
Flexible Ducting
From outside
Diffuser
air supply
setting switch is located
on the rear of the fan case.