Section 7
Service
Alpha Fuzion Sauna Body Pod
78
Figure 7.23.12 Inserting 8-10 foot Wire with Hook.
•
Upper Chassis Data Harness Installation
1. Insert 8-10 foot long wire with hook in the end through display/control panel
opening as shown in Figure 7.23.12
Inserting 8-10 Foot Wire With Hook.
Feed it
through the hood channel to heater opening at hinge plate.
NOTE: Heater must
be removed for installation.
2. Attach new data harness connectors for display/control panel to hook end of wire
as shown in Figure 7.23.13
Connecting Upper Harness to Hook Loop
.
CAREFULLY
draw wire back through harness channel in hood
(NOT THROUGH
HEAT DUCT)
as shown in Figure 7.23.14
Keeping Harness in Hood.
DO NOT
FORCE.
If resistance is met, work wire around channel to find path of least
resistance.
3. Draw display/control connectors through to area behind panel. Leave
approximately 1 foot (30 cm) of the harness to make connection to panel as shown
in Figure 7.23.15
Pulling Harness through Channel.
Remove harness connections
from hook.
4. Attach other end of data harness to hood at heater vent opening by sliding
harness into slot as shown in Figure 7.23.11
Removing/Installing Upper Harness
Cable
. Tighten plastic nut of strain relief.
5. Reattach heater vent screen.
6. Reattach main heater assembly to hinge plate (See Section 7.3).
7. Replace hood onto Alpha Fuzion Sauna Body Pod base chassis (See Section
7.2).
8. Re-install display/control panel (See Section 7.14).
9. Reconnect upper data harness connector to base chassis. Assume proper
connection by twisting locking connector in place.
10. Select and initiate any program to test Alpha Fuzion Sauna Body Pod for proper
function.
Summary of Contents for Alpha Fuzion
Page 1: ...206507 NA AF 10 0813 2 U...