Section 7
Service
Alpha Fuzion Sauna Body Pod
58
7.15 Replacing Sanitary Lamp Ballast
•
Precautions:
Be sure to turn unit OFF at main switch AND disconnect from power source before
going any further with this procedure.
•
Tools/Supplies Required:
Phillips Head screwdriver, 12” x 12” foam pad (or heavy cloth)
•
Preliminary Steps:
Remove main power supply box (See Section 7.10).
•
Ballast Removal/Replacement Steps:
1. Locate ballast on exterior of Power Box as shown in Figure 7.14.1
Male & Female
Terminals of Sanitary Lamp Ballast
.
2. Disconnect two female terminals of lamp assembly from ballast as shown in Figure
7.14.1
Male & Female Terminals of Sanitary Lamp Ballast
.
3. Loosen two Phillips Head screws attaching ballast to power box and remove
ballast.
4. Replace ballast by inserting the new ballast and reversing the procedures above.
7.16 Replacing Face Air Vent(s)
•
Tools Required:
Small flat blade screwdriver, small Phillips Head screwdriver
•
Face Air Vent(s) Replacement Steps:
Note: The louver insert of the face air vent is generally the only part which needs to be
replaced. To replace the louver insert, follow these steps:
1. Using screwdriver, carefully pry louver insert away from the mounting ring as
shown in Figure 7.16.1
Removing Face Air Vent(s)
.
2. Replace louver insert with new part and snap into place.
Note: If mounting ring appears to be damaged, follow these steps:
1. Remove louver insert as described above.
2. Remove two (2) screws from face of mounting ring.
3. Remove mounting ring.
4. Replace with new part and reverse above steps to install.