67
Figure 7.21.1 Removal Program Chip.
7.22 Replacing the Heat Sensor Assembly
•
Precautions:
Be sure to turn unit OFF at main switch or disconnect from power source before
going any further with this procedure.
•
Tools/Supplies Required:
Phillips Head screwdriver, two adjustable Pliers or wrenches, ruler or tape
measure
Heat Sensor connector is attached to rear of display panel. Sensing unit is located inside sauna
chamber (above wooden handle, near air shower holes), as shown in Figure 7.19.3
Harness
Location from Display/Control Panel
and Figure 7.22.1
Heat Sensor Location Inside the Hood
.
Carefully measure and write down the length that the sensing unit extends through the mounting
nut into the sauna chamber. When the replacement sensor is installed, the sensor should
initially extend the same distance into sauna chamber. Sensor may be moved further into
chamber or closer to strain relief nut as determined by temperature test.