206507 NA.AF.10.0813.2.U
Page 1: ...206507 NA AF 10 0813 2 U...
Page 2: ...er s Installation and Service Manual Voice Direct Dial 952 888 2088 Toll Free 877 818 9988 Fax 952 888 8887 Web Site http www nuagebeauty com E mail info nuagebeauty com NUAGE BEAUTY 9220 James Avenue...
Page 3: ...please feel free to contact your NuAge Beauty Sales Representative or our Customer Service Department We look forward to the opportunity of offering additional products and services to you Please forw...
Page 4: ...System Introduction 7 4 2 Alpha Fuzion System Features 8 4 3 Beauty Services 9 4 4 Alpha Fuzion System Contraindications 10 4 5 Water Intake 10 Section 5 Installation 5 1 Opening Shipping Container 1...
Page 5: ...acing Sanitary Lamp Ballast 58 7 16 Replacing Face Air Vent s 58 7 17 Replacing Face Fan Assembly 59 7 18 Replacing Speaker s 61 7 19 Replacing Display Control Panel 62 7 20 Replacing Radio CD Player...
Page 6: ...eady to assist you with a prompt response to any question communicated to us by telephone computer and or fax 1 3 Disclaimer While every attempt is made to ensure the accuracy and completeness of the...
Page 7: ...essed to Alpha Fuzion Sauna Body Pod Owner s Installation and Service Manual NuAge Beauty at the headquarters address listed inside the front cover of this manual along with a date from a copy of the...
Page 8: ...er switch under the bed is turned to OFF NOTE Always turn the main breaker switch under the bed to OFF prior to disconnecting plug from wall plug Avoid using Alpha Fuzion Sauna Body Pod under the foll...
Page 9: ...gen is being administered 8 To disconnect turn power control to the OFF position then remove plug from outlet 9 DANGER Never use pins or other metallic fasteners with this appliance Carefully examine...
Page 10: ...having an equipment grounding conductor and grounding plug The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances...
Page 11: ...the actual dimensions Avoid using Alpha Fuzion Sauna Body Pod under the following conditions Do not install near heat sources such as radiators or in places subject to excessive dust mechanical vibra...
Page 12: ...aps the body s inner resources to improve over all well being along with other holistic techniques The Alpha Fuzion Sauna Body Pod dry heat sauna adjustable settings ergonomically contoured vibratory...
Page 13: ...d The massage bed is contoured to the most comfortable fit for your body Evenly distributed cushioned support eliminates pressure points to allow for the feeling of relaxed air suspension The contoure...
Page 14: ...he following spa services may be offered to personalize any session Table 2 4 1 Spa Services Body Care Skin Care Body Wraps and Masks Clay Mud Herbal Bandage Wrap Mineral Paraffin Thalasso Services Se...
Page 15: ...treatment Recommend no treatment Recommend no treatment Recommend no treatment Recommend no treatment Recommend no treatment during pregnancy Recommend no treatment during lactation Obtain written con...
Page 16: ...ps restraining the Alpha Fuzion Sauna Body Pod carton with utility tool 2 Save exterior packing materials instruction sheet 3 Lift top off carton 4 Remove pieces of cardboard support bridge 5 Remove t...
Page 17: ...tic drawtubes have been preinstalled at factory Figure 4 3 1 Preliminary Installation of Aroma System 3 Carefully remove the four O rings glass expansion chambers and 1 3 oz aroma bottles from their p...
Page 18: ...rtlessly 9 Repeat for three remaining oils 10 Lower the contour bed into position Figure 4 3 2 Installation of Aroma System WARNING The glass expansion chambers should always be screwed in before you...
Page 19: ...ate the bed prop Lift the bed prop into position and lower bed onto it 10 Plug the cords into the outlet according to the label while the bed prop is holding the bed up 11 Make sure the vibration moto...
Page 20: ...apy Pillow is designed for shorter persons to support hips and buttocks Place this cushion at the curvature of the contour bed to prevent body movement Installing Headphones 1 Locate the headphone jac...
Page 21: ...e with radio and television reception It has been type tested and found to comply with the limits for a Class B computing device in accordance with the specifications in Subpart J of Part 15 of FCC Ru...
Page 22: ...ng disassembled If you have any questions concerns and or problems please contact your nearest dealer immediately For operational safety strictly observe the following instructions Do not sit or place...
Page 23: ...rol keys on the Control Panel for initializing each session with an explanation of each key The initialization process described in the Setup key will need to be performed before beginning the first s...
Page 24: ...f the Preprogrammed Session and Personalized Session Press the PROGRAM OPTIONS key to select a session Scroll through the PROGRAM OPTIONS by using the INCREASE or DECREASE keys and press the ENTER STA...
Page 25: ...appropriate system of optional measure of temperature type of F or C and unit of weight of pounds LB or kilograms KG Press the INCREASE Key to change the temperature and the DECREASE key to select app...
Page 26: ...e numbers and return to the OWNER S RECORD in IMPORTANT DOCUMENTATION of Appendix B PC IDENTIFICATION NUMBER PRESS SET UP TO CONTINUE COPYRIGHT 2013 NUAGE BEAUTY MPLS MINNESOTA USA Next press the SETU...
Page 27: ...ady preset for a session There are thirteen different programs to choose from including a Customized Session For specific instructions see below To program Customized Session select from the following...
Page 28: ...3 Aroma R Heat Pad ON Wake up 0 02 Vibration UPPER 2 PRE POST MASSAGE SESSION PRE POST MASSAGE Time Remaining 0 15 Temp 135 F or 55 C Face Air 4 Aroma F Heat Pad ON Wake up 0 02 Vibration BOTH 3 PREH...
Page 29: ...ace Air 4 Aroma FC Heat Pad ON Wake up 0 02 Vibration BOTH 7 RELIEF SESSION RELIEF Time Remaining 0 30 Temp 140 F or 60 C Face Air 5 Aroma FR Heat Pad ON Wake up 0 02 Vibration BOTH 8 CLEANSING SESSIO...
Page 30: ...ake up 0 02 Vibration BOTH 13 CUSTOMIZED SESSION DEFAULT CUSTOMIZED Time Remaining 0 00 Temp OFF F C Face Air OFF Aroma Heat Pad OFF Wake up 0 00 Vibration OFF The Customized Session is listed as a Pr...
Page 31: ...100 F or 40 C press INCREASE or DECREASE to change press ENTER to continue CUSTOMIZED SESSION VIBRATION PATTERN Vibration Pattern BOTH press INCREASE or DECREASE to change press ENTER to continue CUS...
Page 32: ...LAXATION ON press to select ON OFF CLEANSING OFF press ENTER to continue CUSTOMIZED SESSION SUMMARY CUSTOMIZED Time Remaining 0 30 Temp 100 F 40 C Face Air 7 Aroma FR Heat Pad ON Wake up 0 02 Vibratio...
Page 33: ...43 C press INCREASE or DECREASE to change press ENTER to continue Aroma Key The Alpha s unique aroma system allows a choice of four Pure Essential Oils You can choose between the following aromas Vig...
Page 34: ...E to change press ENTER to continue Session Timer Key for Time Remaining in a Session The SESSION TIMER key may be used to set or adjust the duration in minutes for each session An actual session may...
Page 35: ...ace air feature is turned ON the cool airflow refreshes the client s face and head FACE AIR KEY Face Air Level 3 press INCREASE or DECREASE to change press ENTER to continue Heat Pad Key for Back and...
Page 36: ...ontinue WARNING Do not look directly at the ultraviolet lamp located underneath the contour bed for more than fifteen seconds as it may damage your eyes ION UV KEY PREPROGRAMMED SESSION The ION UV is...
Page 37: ...Your Alpha Fuzion Sauna Body Pod Alpha Fuzion Sauna Body Pod may be left ON after a session and the WELCOME screen will be constantly displayed If desired Alpha Fuzion Sauna Body Pod may be turned OF...
Page 38: ...Raise the hood fully Rotate the threaded rings counterclockwise at the bottom of each of the electrical connectors located on either side of the main hinge strut assembly Next pull the connectors up...
Page 39: ...until the hinge slide pins are free as shown in Figure 7 2 1 Hood Alignment of Pins and Hinge Assembly If the slide pins resist movement gently rock the hood side to side while lifting upward 3 When...
Page 40: ...assembly Gently allow hood to slide down onto hinge assembly until the hood pins are fully seated in slots as shown in Figure 7 2 1 Hood Alignment of Pins and Hinge Assembly Hole in hinge assembly abo...
Page 41: ...he floor or an elevated platform next to the Alpha Fuzion Sauna Body Pod for easier work access 2 Remove hood See Section 7 1 Place exterior shell of the hood curved side down on cushioned pad to prev...
Page 42: ...Loosen strain relief bushing by turning plastic nut from the outside of the duct with a wrench as shown in Figure 7 3 4 Removing Heater Harness NOTE It may be necessary to use a second wrench to hold...
Page 43: ...Reconnect strain relief bushing nut and heater screen reversing Step 4 in Removing the Heater Assembly immediately above 4 Replace the hinge plate and secure with five screws and nuts 5 Re attach hea...
Page 44: ...usted by repositioning the pin bolt on the upper hinge assembly As shown in Figure 7 4 1 Pin Bolt on Upper Hinge Assembly The factory generally sets the position of the pin bolt at hole number six 3 U...
Page 45: ...users 6 Select the numbered hole for the pin bolt position to create desired effect and re attach struts and pin bolt to upper hinge assembly Be careful to position the spacers and washers correctly a...
Page 46: ...enches to remove pin bolt and nylon spacers from lower hinge area Note the position of the spacers and washers for proper replacement 2 Remove the struts Strut Replacement Steps 1 Replacement struts a...
Page 47: ...h capability medium large Phillips Head screwdriver Preliminary Procedures Remove hood See Section 7 1 and carefully set aside by placing edge of the hood on a carpeted or padded floor as shown in 7 3...
Page 48: ...ve the struts Note the hole in which the pin bolt was originally mounted Figure 7 6 1 Removing Strut Pin Bolt and Nylon Spacers on Upper Hinge Assembly Figure 7 6 2 Removing Hinge Plate Screws on Base...
Page 49: ...Sauna Body Pod from power source before beginning this procedure 2 Two people may be needed to perform this procedure as bed may be awkward to handle alone Bed Assembly Removal Steps 1 Raise hood to a...
Page 50: ...hown in Figure 7 7 3 Disconnect Electrical Cords from Power Box Cover Figure 7 7 2 Bed Assembly from Base Chassis 4 Carefully lift contour bed to disengage bed prop stand from brackets Lower bed prop...
Page 51: ...rm this procedure Bed weighs approximately 60 lbs 27 kg and may be awkward to handle alone Bed Assembly Replacement Steps 1 Raise hood until it reaches fully open position 2 Set six 6 bed support ball...
Page 52: ...cker service removable Preliminary Steps 1 Remove bed assembly from lower chassis See Section 7 7 2 Place bed upside down on soft clean work surface 3 Remove screws from motor guard Set screws and gua...
Page 53: ...r s using two 2 flange bolts Apply Loctite threadlocker or similar product to threads prior to insertion 2 Reinstall rheostats inside bed support cup s Affix rheostat to support cup with new retaining...
Page 54: ...ower supply box as shown in Figure 7 10 2 Disconnecting Transformer from Power Box Main Power Supply Box Removal Steps 1 Release main power supply box cover by removing four screws which hold cover an...
Page 55: ...Disconnect four aroma pump plugs and sanitary lamp plug from the side of the power supply box as shown in Figure 7 10 4 Aroma Pump Wiring Connection 7 Disconnect two pin and six pin connectors from t...
Page 56: ...ion 4 Connect ballast transformer still connected to wiring harness to side of box 5 Connect two pin and six pin connectors to power supply box as shown in Figure 7 10 5 Connector Diagram 6 Connect bl...
Page 57: ...illips Head screwdriver 12 x 12 foam pad or heavy cloth Pliers or vise grip pliers Preliminary Steps Remove main power box See Section 7 11 Replacing Aroma Pumps 1 Raise bed prop stand out of the way...
Page 58: ...of the aroma pump well by pulling up on the bushing at the same time as you squeeze the bushing with pliers at the center as shown in Figure 7 11 1 Removing Aroma Assembly Strain Relief 4 Cut the cabl...
Page 59: ...Section 7 Service Alpha Fuzion Sauna Body Pod 54 Figure 7 11 2 Aroma Pump s Location Figure 7 11 3 Pump Plug Location 1 2 4 3 1 2 3 4...
Page 60: ...place the bottle just removed NOTE Be careful to use the same exclusive oil blend 2 Screw aroma bottle into lower threads of brass nebulizer NOTE Be certain rubber O ring is in place between bottle an...
Page 61: ...with your finger with the aroma pump turned on for approximately 15 seconds This will cause air to flow backward in the inner oil jet and clean the inside jet 7 14 Replacing Sanitary Lamp Assembly Pre...
Page 62: ...ctrical plug from main power supply box Unplug the female terminals on the electrical cord from the male terminals on the cord from ballast as shown in Figure 7 11 3 Pump Plug Location and Figure 7 14...
Page 63: ...Phillips Head screws attaching ballast to power box and remove ballast 4 Replace ballast by inserting the new ballast and reversing the procedures above 7 16 Replacing Face Air Vent s Tools Required S...
Page 64: ...rther with this procedure Tools Required Phillips Head screwdriver Face Fan Assembly Removal Steps 1 Remove four 4 screws affixing grill and face fan assembly to unit as shown in Figure 7 17 2 Face Fa...
Page 65: ...Section 7 Service Alpha Fuzion Sauna Body Pod 60 Figure 7 17 1 Face Fan Assembly Figure 7 17 2 Face Fan Grill Figure 7 17 3 Pin Connector to Face Fan Motor...
Page 66: ...re to turn unit OFF at main switch and disconnect from power source before going any further with this procedure Tools Required Phillips Head screwdriver Speaker Removal Steps 1 Remove four screws hol...
Page 67: ...going any further with this procedure Tools Required Phillips Head screwdriver PC Display Control Panel Removal Steps 1 Remove three screws holding PC display control panel in place 2 Gently pull top...
Page 68: ...om Display Control Panel to ensure that wiring harnesses are installed properly NOTE Install connectors correctly with locking tabs in proper position where applicable Improper connector installation...
Page 69: ...ng Radio CD Player Precautions Be sure to turn unit OFF at main switch or disconnect from power source before going any further with this procedure Tools Supplies Required Phillips Head screwdriver DI...
Page 70: ...released assert pressure on rear of radio unit and remove through front of display panel Stereo Radio Replacement Steps 1 Check mounting bracket for firm connections crimps to display panel of upper a...
Page 71: ...te that one end of the replacement chip has a small notch in the center NOTE Be certain the chip is installed with this notch toward the TOP of the control panel If chip is installed upside down the L...
Page 72: ...ttached to rear of display panel Sensing unit is located inside sauna chamber above wooden handle near air shower holes as shown in Figure 7 19 3 Harness Location from Display Control Panel and Figure...
Page 73: ...if necessary until sensor can be removed from Strain Relief nut by pulling back into display panel area Heat Sensor Assembly Replacement Steps 1 Carefully insert replacement heat sensor cable through...
Page 74: ...source before proceeding any further Tools Supplies required Phillips Head screwdriver wire cutter small needlenose pointed Pliers wire puller 7 8 or 1 2 5 m length of stiff wire with a small tight ho...
Page 75: ...x Extension Cable Installation Reverse removal steps as explained in 1 4 above 1 Insert end of cable with five lug connectors through hole in base chassis to left of main hinge assembly as shown in Fi...
Page 76: ...ck using a needle nose pliers or similar tool When ring is off remove headphone jack PC board and pull through speaker opening bringing six pin connector with it 7 Disengage six pin connector segments...
Page 77: ...Section 7 Service Alpha Fuzion Sauna Body Pod 72 Figure 7 23 4 Position of Telephone Computer Jack Figure 7 23 5 Lower Harness Inserting Figure 7 23 6 Lower Harness Terminals...
Page 78: ...sharp fiberglass ends 2 Next insert six pin connector of long wire and feed through until it can be grasped and pulled through into base cavity power box area 3 Insert wire with spade connectors throu...
Page 79: ...wer chassis toward face fan opening Pull through upper area of cavity just below deck surface to avoid getting stuck in narrow lower area DO NOT FORCE this procedure If you become stuck reverse the pr...
Page 80: ...h PC board Left side speaker and grill Face fan assembly Main power box 13 Select and initiate any program to test Alpha Fuzion Sauna Body Pod for proper function Headphone PC Board Extension Cable Re...
Page 81: ...harness from wire loop Install headphone jack with PC board into mounting hole using small retaining ring Tighten snugly with needle nose pliers or similar tool DO NOT OVERTIGHTEN as finish may crack...
Page 82: ...raightening tabs within heat chamber and remove 5 Using wrench release cable as shown in Figure 7 23 11 Removing Installing Upper Harness Cable from heat chamber area by loosening plastic nut of strai...
Page 83: ...re around channel to find path of least resistance 3 Draw display control connectors through to area behind panel Leave approximately 1 foot 30 cm of the harness to make connection to panel as shown i...
Page 84: ...Section 7 Service Alpha Fuzion Sauna Body Pod 79 Figure 7 23 13 Connecting Upper Harness to Hook Loop Figure 7 23 14 Keeping Harness in Hood Figure 7 23 15 Pulling Harness through Channel...
Page 85: ...ossible Cause Remedy Cross Reference No Electrical Power Bad power connection Incorrect power source Blown fuse or circuit breaker Machine not turned ON Secure power connections to wall receptacle and...
Page 86: ...face panel Hood base offset Move the Unit to a level padded or carpeted surface Make sure all balls are in place Tighten loose bolts on the base of the motor assembly clockwise with an adjustable wre...
Page 87: ...ut assembly This is a common problem in re assembly of the unit after installation E Check Circuit Breaker Fuse to wall receptacle F Use voltmeter to check for proper voltage at wall receptacle G Disc...
Page 88: ...r connectors into main box as well Re install main power box being careful not pinch any wires Re power unit 2 Select program and start waiting 1 2 minutes for heater to initiate or repeat voltage che...
Page 89: ...is a common problem area especially re assembly following installation G If display is still inoperative 1 Carefully remove three screws holding display panel in place 2 Carefully remove display asse...
Page 90: ...supplier for further troubleshooting advice or replacement of main power box VI Aroma Pump s Inoperative A Check Liquid Crystal Display LCD indicator on display screen CONTROL PANEL to verify appropr...
Page 91: ...ifice to penetrate the clog and clear a pathway 6 If air and oil still do not flow through orifice into glass chamber when system is activated replace brass nebulizer VIII Ultraviolet Sanitary Lamp In...
Page 92: ...plug all plugs from top of power box and remove contour bed assembly See Section 7 7 G Place contour bed upside down on floor Use a Phillips Head screwdriver to remove the center ball socket and rheos...
Page 93: ...le to allow for a better signal reception 2 Remove display screen CONTROL PANEL See Section 7 19 Check for firm connection of antenna to back of stereo radio unit NOTE Because no outside antenna is av...
Page 94: ...l Cleaning Mandatory Use of Pre Approved Solution Pre trained personnel must do all cleaning via NuAge Beauty s written instructions All plastics and poly carbonate surfaces including the inside and o...
Page 95: ...ior hood or on the side panels of the Alpha Fuzion Note Abrasive detergents and scrubbing must not be used to clean the unit This may result in serious damage to the plastic surfaces of the unit In ad...
Page 96: ...g Contact Surfaces Bed Head Pillow Interior of Shell 1 Use Accel TB 05 Disinfectant on all contact surfaces AFTER EACH USE to present a clean sanitary appearance and feel for each new client 2 Let sol...
Page 97: ...f Temperature 80 F to 180 F 26 C to 82 C Accuracy Temperature within plus or minus five degrees Displays Liquid Crystal Digital LCD and Light Emitting Diodes LED Keys Struts Expected to lose three to...
Page 98: ...Chambers Headphones 2 Neck Drapes 4 Filter Pick up Tubes 4 O Rings 2 Cleansing Pure Essential Oil Blend 2 Relaxation Pure Essential Oil Blend 2 Fitness Pure Essential Oil Blend 2 Vigor Pure Essential...
Page 99: ...BY DISTRIBUTED BY NUAGE BEAUTY 9220 JAMES AVENUE SOUTH MINNEAPOLIS MN 55431 USA Tel 952 888 2088 Fax 952 888 8887 WARNING TO PREVENT FIRE OR SHOCK HAZARD 1 DO NOT EXPOSE UNIT TO RAIN 2 DO NOT PLACE T...
Page 100: ...ge Beauty NuAge Beauty 9220 James Avenue South Minneapolis MN 55431 USA Tel 952 888 2088 877 818 9988 Fax 952 888 8887 Serial Number Date of Purchased Model Number Business Name Owner s Name Mailing A...
Page 101: ...be returned to NB for evaluation and or repair f Parts are provided on an Exchange Basis Defective parts must be returned to NB Shipping costs reimbursement will be determined by NB Technical Manageme...
Page 102: ...to Customer at the current NB published Time and Materials Rates and will not be covered under this Product Warranty j Use ONLY the SYB approved Accel TB Cleaning Solution Use of any and all other cle...
Page 103: ...sentations statements or conditions oral or otherwise of any kind whatsoever regarding this Product Warranty 13 JURISDICTION AND GOVERNING LAW Disputes arising under this Extended Warranty Agreement s...