RECORD DATA TO BE COMPLETED & KEPT BY USER:

 

 

 
PLACE OF PURCHASE 

................................

..................................……………………….

         DATE

 

……....................

 

 
 
ADDRESS & TEL. NO. 

.…...……………….......................................…............................................................................. 

 
 
.......................

..........................................................................................................………………………..........…………

 

 
 

............................................................................................................................

.....………………………..........…………

 

 
 
APPLIANCE SERIAL NO. 

..............................................  

 
 

INSTALLED BY 

........................................………………………………….

        GAS SAFE. NO 

...................................  

 
 

INSTALLATION & SERVICING INSTRUCTIONS 

FOR CHESNEYS ALCHEMY EVOLUTION PLUS GAS FIRES  

(NATURAL GAS ONLY)

 

FOR DECORATIVE PURPOSES ONLY

 

 

NATURAL GAS MODELS:  N2, N2I, N3R, N3I, N5R & N5 

 

THIS APPLIANCE MUST BE INSTALLED & SERVICED BY A PROPERLY QUALIFIED 

(IN ACCORDANCE WITH LOCAL & NATIONAL CODES) INSTALLATION ENGINEER. 

 

IMPORTANT:

 

 

 

BEFORE PROCEEDING WITH THE INSTALLATION READ THESE INSTRUCTIONS CAREFULLY. THESE INSTRUCTIONS 

SHOULD BE KEPT IN A SAFE PLACE FOR FUTURE REFERENCE AND SERVICING DETAILS. 

 

PRIOR TO INSTALLATION ENSURE THAT THE GAS TYPE AND PRESSURE ARE AS STATED ON THE APPLIANCE DATA 

PLATE. 

 

SIMULATED COALS, OR SIMULATED LOGS, TOGETHER WITH SIMULATED BLACK BARK, ARE SUPPLIED WITH THIS 

APPLIANCE. DO NOT USE REAL COALS, LOGS OR BARK, AS THIS IS DANGEROUS. IF THE SIMULATED COALS, 

SIMULATED LOGS OR SIMULATED BLACK BARK NEED RENEWING PLEASE OBTAIN SUITABLE REPLACEMENTS FROM 

YOUR STOCKIST. 

 

                                     

APPLIANCE DATA

 

   

GAS TYPE: SEE DATA PLATE. 

 

   

BURNER: NU-FLAME EVOLUTION 

PLUS

 STAINLESS STEEL 

 

   

FLAME SAFETY: OXYGEN DEPLETION & FLAME FAILURE DEVICE STANDARD TO ALL MODELS. 

 

   

APPLIANCE INLET WORKING PRESSURE: SEE DATA PLATE. 

 

   

IGNITION: PIEZO. 

 

 

 

INLET CONNECTION: 8MM COMPRESSION FITTING. 

 

 

 

NETT 

HEAT INPUT: SEE DATA PLATE.

 

Summary of Contents for CHESNEYS ALCHEMY EVOLUTION PLUS N2

Page 1: ...can be varied to any point between high and low as desired c To turn off depress knob and turn clockwise depressing knob at each point as you go all the way round to off IMPORTANT NOTES d This applian...

Page 2: ...EPT IN A SAFE PLACE FOR FUTURE REFERENCE AND SERVICING DETAILS PRIOR TO INSTALLATION ENSURE THAT THE GAS TYPE AND PRESSURE ARE AS STATED ON THE APPLIANCE DATA PLATE SIMULATED COALS OR SIMULATED LOGS T...

Page 3: ...at hearth level and observe smoke If there is a definite flow into the flue aperture proceed with installation If there is not a definite flow into the flue aperture preheat the flue for approximatel...

Page 4: ...OF THE APPLIANCE Having ensured that the appliance application is correct and the requirements of the flue specification ventilation demands and the gas supply are correct proceed with the installatio...

Page 5: ...d remove the sellotape and ensure that the slots in the burner insulation pad are clear It is very important to ensure the following in order not to void the warranty 1 The gap under the burner block...

Page 6: ...cific layout has been devised to suit each basket b Where logs rest on the fire bed they should be supported by a bark chipping or chippings This achieves a good airflow around the log in order to avo...

Page 7: ...the back bars of the firebasket Position the two side logs resting on the back log and leaning high up against the side bars Position the straight left hand centre log resting on a bark piece at the f...

Page 8: ...re at the back of the burner against the back bars of the firebasket Position the two side logs resting on the back log and leaning against the side bars Position the straight left hand centre log res...

Page 9: ...ack of the burner against the back bars of the firebasket Position the two side logs resting on the back log and leaning high up against the side bars Position the straight left hand centre log restin...

Page 10: ...against the back bars of the firebasket Position the two side logs resting on the back log and leaning against the side bars Position the straight left hand centre log resting on a bark piece at the...

Page 11: ...will cease in a few hours If it does not consult your dealer straight away d Open fires are a hazard it is recommended that a guard be fitted to provide protection for children the elderly or infirm...

Page 12: ...y with CE approval Note It is a condition of the warranty that you do not return any parts to us unless we request you to do so For example if we request that the burner only is returned and you send...

Reviews: