Chapter 6 - Monitoring Systems
Uploading SAF-TE Controller Card Firmware
103
Uploading SAF-TE Controller Card Firmware
The following information describes the procedures to upload new firmware to
the SAF-TE Controller card. The firmware can be uploaded in a “live”
environment. There is no need to down the system to perform this function.
1
Connect one end of the null-modem RS-232 cable to the SAF-TE Service port
located on the rear panel of the enclosure.
Connecting the RS-232 Cable
The cable is a female-to-female DB-9 null-modem cable.
2
Connect the other end of the cable to either a host system’s serial
communication port or a VT-100 type terminal.
3
On a host system, run a terminal emulation program or start the terminal.
4
Verify the communication parameters are as follows:
•
9600 Baud (optional 19,200)
Baud rate set by Switch 6 – up for 19,200 and down for 9,600 (verify the setting
by pressing the Alarm Reset button and noting the condition of the Drive Status
LED for Drive slot 5.
•
8 Data bits
•
1 Stop bit
•
None (parity)
•
Flow Control Off
5
At the cursor, type <Control-E>.
CTRL 1
CTRL 2
SAF-TE
Controller 1: Service Port
SAF-TE Service Port
Controller 2: Service Port
4100FS.book Page 103 Tuesday, July 8, 2003 4:35 PM
Summary of Contents for 4100FS
Page 2: ...4100FS book Page 2 Tuesday July 8 2003 4 35 PM...
Page 8: ...Table of Contents iv 4100FS book Page iv Tuesday July 8 2003 4 35 PM...
Page 12: ...About this Manual Features viii 4100FS book Page viii Tuesday July 8 2003 4 35 PM...
Page 30: ...Chapter 1 Getting Started Audible Alarm 18 4100FS book Page 18 Tuesday July 8 2003 4 35 PM...
Page 166: ...Index 154 4100FS book Page 154 Tuesday July 8 2003 4 35 PM...
Page 167: ...4100FS book Page 155 Tuesday July 8 2003 4 35 PM...