15
CODE
MEANING
SOLUTION
32
Solenoid weld-
ed. Caused by
wiring short
circuit in con-
tactor wiring or
contactor coil.
Internal control
system check
failure.
Check wiring and
solenoids. Turn
keyswitch off and
on. Call for service if
problem persists.
33
Solenoid did not
close. Caused
by wiring short
circuit in con-
tactor wiring or
contactor coil.
Internal control
system check
failure
Check wiring and
solenoids. Turn
keyswitch off and
on. Call for service if
problem persists.
37
Throttle fault.
Internal control
system check
failure.
Check joystick and
wiring. Turn machine
off and then on. If
problem continues
call for service
36
Right brake
overcurrent
Call for service.
39
Left brake over
-
current
Call for service.
3A
Right brake
circuit open
Turn on brake lever
then turn machine off
and then on. If prob
-
lem continues call for
service.
40
Left brake cir
-
cuit open
Turn on brake lever
then turn machine off
and then on. If prob
-
lem continues call for
service.
F42
The brush mo-
tor or a drive
motor is ex-
ceeding the cur-
rent limit set in
the controller.
Select lower pad
pressure setting.
Check brakes. Turn
machine off and then
on. If problem contin
-
ues call for service.
44, 4C,
45, 59, 60
Caused by wir-
ing short circuit
in drive wiring
or shorted drive
motor. Carbon
brushes need
service.
Check wiring and
drive motor for short
circuit. Correct prob-
lem if found. Check
carbon brushes. If
problem continues
call for service.
4D, 46, 61
Caused by wir-
ing short circuit
in brush wir-
ing or shorted
brush motor.
Carbon brushes
need service.
Check wiring and
brush motor for short
circuit. Check car
-
bon brushes. Correct
problem if found. If
problem continues
call for service.
58
The deceleration
of the brush
motor or drive
motor exceeded
set parameters.
Example: Tried
to slow down
or stop on too
steep a hill.
Turn machine off and
then on. If problem
continues call for
service.
CODE
MEANING
SOLUTION
62
Wired incor-
rectly. Internal
control system
failure.
Check wiring. Turn
machine off and then
on. If problem contin
-
ues call for service.
63
Caused by wir-
ing short circuit
in contactor wir-
ing or contactor
coil.
Check wiring and con
-
tactor for short cir-
cuit. Correct problem
if found. If problem
continues call for
service.
Battery Charger Error Codes
Always confirm the battery charger settings match the
batteries installed if an error code is displayed.
If any error codes are displayed:
• Unplug the charger.
• Check the battery connections are clean and tight.
• Check the electrolyte level in each cell (flooded
batteries only).
•
Try charging again. First charge on new batteries
may result in a code.
Code
Meaning
E01
Max battery V reached. Verify charger is set
to match the installed batteries
E02
Charger maximum internal temperature
reached. Charge with Upper Body open, and
Storage Compartment cover open.
E031 Phase 1 safety timer 18h reached. Batteries
need replaced.
EDI
Phase 1 battery voltage failed to rise. If
batteries are new charge again, otherwise
replace the batteries.
E032
Phase 2 safety timer 10hr reached. If bat
-
teries are new, try charging again. If batter
-
ies are >1yr old they need replaced
EDU
Phase 2 batteries require excessive current
to hold voltage. If batteries are new charge
again, otherwise replace the batteries.
SCt
Overall Safety Timer. Replace the batteries.
Srt
Charger internal short - replace the charger.