Always use a defoamer when foaming occurs to prevent vacuum motor damage.

Never use water above 130

°

 F (54

°

C).

Do not use outdoors or where temperature is below freezing.  Protect your machine
from any extremes in temperatures.

Do not let the pump run dry. Turn the pump off and refill the tank when cleaning solution
gets low.

Flush the machine with an acid de-scaler regularly (monthly or more often) to prevent
a build-up of minerals or chemicals in the pump and heat systems.  Follow the flush
with a clear water rinse to remove any particles and to rinse the acid from the machine.

Use approved chemicals only. All chemicals should be mixed thoroughly.  Liquid
chemicals are recommended to prevent powder buildups. A pH between 6 and 9 is
recommended.  The use of high alkaline detergents or strong acids will accelerate the
wear of the pump and seals, and will void the warranty.

All extension cords must have a rating of at least 12/3 (#12 cord). Extension cords
should be no longer than 50 feet.  Replace the plug immediately if the ground prong
becomes damaged or is broken off.

56041886

Summary of Contents for COBRA-H2

Page 1: ...arly monthly or more often to prevent a build up of minerals or chemicals in the pump and heat systems Follow the flush with a clear water rinse to remove any particles and to rinse the acid from the...

Page 2: ...hair fingers and all parts of body away from openings and moving parts Do not pick up anything that is burning or smoking such as cigarettes matches or hot ashes or any health endangering dusts Turn o...

Page 3: ...has a grounding plug that looks like the plug illustrated in Figure 1 below A temporary adapter illustrated in Figures 2 and 3 may be used to connect this plug to a 2 pole receptacle as shown in Figu...

Page 4: ...where the vacuum hose attaches to the machine Latch 6 Open the latches to access the base compartment which contains the motors and heater Drain Gate 7 Open this gate to drain the recovered solution...

Page 5: ...nutes to reach operating temperature 6 Turn the pump on Turn the vacuum on NOTE the pump has a built in pressure switch the pump runs only when you are spraying 7 Begin cleaning using the correct hose...

Page 6: ...seals are damaged Internal vacuum hose is cracked Recovery tank lid is not closed is cracked or gasket is damaged Recovery tank is warped or cracked Debris impeding air movement on vac motor impellor...

Page 7: ...1 22 40 41 42 43 44 45 46 47 53 48 55 49 58 50 51 52 62 69 14 16 66 67 68 COBRA H2 CSA 08 10 2007 19 56 24 11 12 13 14 33 28 32 35 63 38 37 30 65 61 60 59 58 69 57 55 54 53 36 31 34 22 25 26 29 27 31...

Page 8: ...Heat Exchanger complete 36 5 Bolt 1 4 20 X 3 4 37 8 Lock nut 1 4 20 38 455 Bracket heater mount 39 76 Hose Clamp 40 270 Bolt 1 4 20 X 5 41 137 Washer split lock 42 136 Nut finish 1 4 43 14 Washer fla...

Page 9: ...les mois ou plus souvent pour emp cher le d p t de min raux ou de produits chimiques dans les syst mes de pompe et de chauffage Rincer apr s le lavage avec de l eau claire pour liminer les particules...

Page 10: ...les cheveux les doigts et tout autre partie du corps loin des ouvertures et des pi ces mobiles Ne pas ramasser quoi que ce soit qui br le ou qui fume comme des cigarettes allumettes ou cendres chaudes...

Page 11: ...connecter cette fiche une prise p les comme le montre la Figure 2 si une prise correctement mise la terre n est pas disponible Il faut utiliser l adaptateur temporaire uniquement jusqu au moment o un...

Page 12: ...tion 5 C est l que le tuyau flexible d aspiration est fix la machine Loquet 6 Ouvrir les loquets pour acc der au compartiment inf rieur qui contient les moteurs et l l ment chauffant Opercule du drain...

Page 13: ...eindre la temp rature de fonctionnement 6 Mettre la pompe en marche Mettre l aspiration en marche NOTE La pompe dispose d un pressostat int gr elle ne fonctionne que lorsque vous vaporisez 7 Commencer...

Page 14: ...mpl tement ferm ou les joints d tanch it sont endommag s Le tuyau flexible int rieur d aspiration est fendu Le couvercle du r servoir de r cup ration n est pas ferm est fendu ou le joint d tanch it es...

Page 15: ...425 322 0133 800 257 7982 FAX 425 322 0136 11015 47th Ave W Mukilteo WA 98275 VISIT US AT http www usproducts com...