MIDI TO MICROPLEX and DMX 512
In this application, MIDI note commands are converted to Microplex and DMX 512 dimmer levels.
CONNECTOR
OPERATION
Microplex IN
Not Used
Microplex OUT
Output Microplex (64 or 128)
DMX IN
Not Used
DMX out
Output DMX 512
MIDI / Analog
Input MIDI
Luma-net
Not Used
RS-232
Not Used
JUMPER LOCATIONS
P4 & 5
P7
JP6 & 7
JP8 & 9
JP10
JP11
JP12
JP13
OPEN
CLOSED
N/A
1-2
1-2
2-3
2-3
2-3
P6
P8
JP1
DMX OUT CABLE
N/A
N/A
POSITION 2
JP4
DIPSWITCH POSITIONS
C1
C2
C3
C4
ADDRESS 1 - 7
A8
UP
UP
DN
DN
A1-4 SELECTS MIDI CHAN, 5 UP SETS IGNORE NTOFF
DN:64
MIDI Channel 1 - 16 can be selected with switch A1-4 (see chart at end).
Velocity of MIDI Note On messages set respective dimmer levels. C0 = dimmer channel 1.
Note Off (or Note On = 0) will turn off channel unless A5 is in the up position.
DMX or Microplex output is sent as either 64 or 128 channels, depending on the setting of switch A8.
INTERFACE UNIT
Software Revision 1.05, Version A
MIDI TO MICROPLEX and DMX 512
NSI CORPORATION
9