MICROPLEX TO AMX 192
In this application, Microplex is converted to AMX-192. The 5 pin XLR may be replaced with a 4 pin XLR
(USITT) if desired.
CONNECTOR
OPERATION
Microplex IN
Input Microplex
Microplex OUT
Not Used
DMX IN
Not used
*DMX out
Output AMX 192 (64 or 128 channels)
MIDI / Analog
Not used
Luma-net
Not Used
RS-232
Not Used
JUMPER LOCATIONS
P4 & 5
P7
JP6 & 7
JP8 & 9
JP10
JP11
JP12
JP13
OPEN
OPEN
N/A
N/A
2-3
2-3
N/A
2-3
P6
P8
JP1
DMX OUT CABLE
N/A
N/A
N/A
JP3
DIPSWITCH POSITIONS
C1
C2
C3
C4
ADDRESS 1 - 7
A8
UP
DN
DN
DN
N/A
DN:64
Microplex is converted channel to channel so address is not used.
AMX output is sent as either 64 or 128 channels, depending on the setting of switch A8.
*IMPORTANT - Move AMX output connector jumper from JP4 to JP3.
INTERFACE UNIT
Software Revision 1.05, Version A
MICROPLEX TO AMX 192
NSI CORPORATION
7