INSTALLATION/SET-UP
The following instructions & diagrams show the Harmsco
®
Hurricane
®
Swing Bolt
Water Filter housing with typical plumbing hook-up requirements. All steps of the
installation are to be performed by qualified personnel.
1. Always adhere to state and local plumbing codes and requirements for
design and installation.
2. Mount and secure housing using the holes at the base of the legs -
see Installation Diagrams, pages 8-11.
Models HUR 5X170FL & HUR 8X170FL have two lifting lugs welded onto
the lid for positioning of the housing. Swing bolts must be engaged and the
housing must be empty prior to using the lifting lugs.
3. Bond the filter housing utilizing the grounding lug on the leg.
- must be performed by a qualified electrician
.
4. Install incoming water supply with shut off valve to flange marked "Inlet".
5. Install return line with shut off valve to flange marked “Outlet”.
6. Install plugs or valves in drain lines into the FPT couplings located at
the bottom center and side of housing.
7. Install plugs or pressure gauges into the gauge ports.
8. Install plug or valve into the vent port.
9. Refer to Specifications, Installation Block Diagram & Installation Diagrams
for more details, pages 6-11.
Notes:
●
Shut-off valves shall be installed on inlet and outlet to isolate the filter
when
servicing.
●
To protect against electrolysis, all filters shall be bonded.
Failure to properly bond the filter will void all warranties.
●
Valves, plugs and pressure gauges are not provided.
●
Use gaskets, sealants and/or expansion/vibration coupling materials
appropriate
for
the
application.
●
Flush unit (through outlet) to drain for 10 minutes at recommended flow
rates
prior
to
use.
●
For cartridge replacement, see pgs. 12 - 18, 24.
●
For models HUR 3X170FL, HUR 5X170FL & HUR 8X170FL, make
sure sufficient space is available to rotate lid away from housing
allowing access to all cartridges.