NSF HUR 1X170FL Installation And Operation Manual Download Page 11

Copyright Harmsco

®

 Inc. 

All rights reserved. 
1243-HP, MANUAL - HUR FL  

 

 

                                 

 

 

 

        

Page 11 of 25

 

HARMSCO

®

 Hurricane

®

 

Swing Bolt Water Filters 

 

Installation Diagram 

Model HUR 8X170FL 

Summary of Contents for HUR 1X170FL

Page 1: ...n Products With Patented Up Flow and Tangential Rotational Flow Filtration Technology www harmsco com 561 848 9628 HARMSCO Hurricane Swing Bolt Water Filters Models HUR 1X170FL HUR 3X170FL HUR 5X170FL...

Page 2: ...0FL are equipped with pipe flanges on both the inlet and the outlet cartridge lifting handle s part 362 L All models are NSF Certified per Standard 61 when used with Genuine Harmsco Hurricane HC 170 c...

Page 3: ...nding lug is provided 4 After unit is installed flush through outlet to drain for 10 minutes at recommended flow rates prior to use 5 Always isolate unit and relieve pressure before servicing 6 Utiliz...

Page 4: ...ange Install plug or appropriate valve into the vent port provided Lubricate Swing Bolt Assemblies all models Davit Assemblies HUR 3X170FL HUR 5X170FL HUR 8X170FL using Food Grade grease with PTFE and...

Page 5: ...pply with shut off valve to flange marked Inlet 5 Install return line with shut off valve to flange marked Outlet 6 Install plugs or valves in drain lines into the FPT couplings located at the bottom...

Page 6: ...ft 4 5 ft 8 5 ft 14 0 ft Bonding H ousing shall be bonded in accordance w ith all applicable codes A grounding lug is prov ided on the leg H ousing Material Stainless Steel C onstruction All w etted...

Page 7: ...Copyright Harmsco Inc All rights reserved 1243 HP MANUAL HUR FL Page 7 of 25 HARMSCO Hurricane Swing Bolt Water Filters Installation Block Diagram Models with HP suffix 200 psi...

Page 8: ...Copyright Harmsco Inc All rights reserved 1243 HP MANUAL HUR FL Page 8 of 25 HARMSCO Hurricane Swing Bolt Water Filters Installation Diagram Model HUR 1X170FL...

Page 9: ...Copyright Harmsco Inc All rights reserved 1243 HP MANUAL HUR FL Page 9 of 25 HARMSCO Hurricane Swing Bolt Water Filters Installation Diagram Model HUR 3X170FL...

Page 10: ...Copyright Harmsco Inc All rights reserved 1243 HP MANUAL HUR FL Page 10 of 25 HARMSCO Hurricane Swing Bolt Water Filters Installation Diagram Model HUR 5X170FL...

Page 11: ...Copyright Harmsco Inc All rights reserved 1243 HP MANUAL HUR FL Page 11 of 25 HARMSCO Hurricane Swing Bolt Water Filters Installation Diagram Model HUR 8X170FL...

Page 12: ...alled from experiencing a reverse flow that could cause damage 2 Open Side Drain and let housing drain completely 3 Loosen all Eye Nuts of Swing Bolts by 1 2 turn increments counter clockwise to gradu...

Page 13: ...ENT cont 5 When all of the Swing Bolt hardware is disengaged the Lid can be removed 5 a For Model HUR 1X170FL the Handles on the Lid are used to raise and remove the Lid Note The Lid must be raised su...

Page 14: ...e Housing O ring may stick to Lid To prevent this it is suggested to raise the Lid about 1 8 inch and move the Lid Davit Assembly slightly sideways to free the O ring from Lid while keeping the O ring...

Page 15: ...cont 6 Install Cartridge Handle s part 362 L to Cartridge s Tighten securely to seal with Top End Cap to prevent by passing of the Cartridge Exploded View Cartridge Lifting Handle Part 362 L Top End C...

Page 16: ...to prevent by passing A clockwise rotating motion will help to position the Cartridge while engaging the Stand pipe Coupling Confirm all Cartridge Handle assemblies are fully installed with all Cartri...

Page 17: ...g into channel of Housing 11 Return Lid to closure position and maintain alignment of Lid on Housing Lower lid onto Housing O ring Make sure O ring stays in the channel of the Housing Do not allow til...

Page 18: ...e Nuts are uniformly tight Make sure Lid position and alignment to Housing is maintained 14 Start the flow of water by first opening the inlet valve and allow the housing to completely fill then open...

Page 19: ...80 113 5 227 1 340 7 454 2 567 8 681 4 GPM LP M Pressure Drop vs Flow Rate Curve Harmsco HUR 1X170FL Hurricane HC 170 20 Cartridge Qty 1 with clean water Delta P PSI Bar 8 0 5516 7 0 4826 6 0 4137 5 0...

Page 20: ...rve Harmsco HUR 3X170FL Hurricane HC 170 20 Cartridges Qty 3 with clean water 0 100 200 300 400 500 378 5 757 1 1 135 6 1 514 1 1 892 7 GPM LP M Delta P PSI Bar 10 0 6895 9 0 6205 8 0 5516 7 0 4826 6...

Page 21: ...5 757 1 1 135 6 1 514 2 1 892 7 2 271 2 2 649 8 3 028 3 GPM LP M Pressure Drop vs Flow Rate Curve Harmsco HUR 5X170FL Hurricane HC 170 20 Cartridges Qty 5 with clean water Delta P PSI Bar 8 0 5516 7 0...

Page 22: ...7 1 1 514 2 2 271 2 3 028 3 3 785 4 4 542 5 5 299 6 GPM LP M Pressure Drop vs Flow Rate Curve Harmsco HUR 8X170FL Hurricane HC 170 20 Cartridges Qty 8 with clean water Delta P PSI Bar 8 0 5516 7 0 482...

Page 23: ...ults clean cartridges with pressure nozzle using standard hose Direct spray at an angle to remove particulate Special Cleaning Procedures For oils soak cartridge in a solution of tri sodium phosphate...

Page 24: ...re to contact Tube Sheet of housing 6 Position housing O ring seal in groove of housing 7 Position Lid onto housing and properly align on O ring before applying Swing Bolts Do not allow tilting or coc...

Page 25: ...ned from outside sources and is considered accurate Temperature ratings flow rates and chemical resistance can be affected by a number of unknown factors For this reason we do not assume any liability...

Reviews: