CARTRIDGE REPLACEMENT
1. Isolate unit from all water sources (close I/O lines) and relieve pressure to
housing by first opening the housing’s “Bottom Drain” and let drain completely.
See Installation Diagrams (pgs. 8-11). This will protect the cartridges (installed)
from experiencing a reverse flow that could cause damage.
2. Open Side Drain and let housing drain completely.
3. Loosen all Eye Nuts of Swing Bolts by 1/2 turn increments counter-clockwise to
gradually step down load applied to swing bolts. Repeat process as needed.
4. Fully loosen Eye Nuts but do not remove from Swing Bolt. Lift Washer above
Tangs in Lid Cleats and allow Swing Bolt to rotate downward along the side of
the housing’s Tank Wall.
Loosen Tighten
Eye Nut
Washer
Swing Bolt
Lid Cleat
Tang of
Lid Cleat
Swing Bolt,
Eye Nut & Washer
Disengaged
from Lid
Tank Wall