Hurricane
®
Swing Bolt Water Filters
CARTRIDGE REPLACEMENT cont.
7. With swing bolts disengaged and lid removed, install Cartridge/Handle
assembly(s) onto Stand-pipe(s). Position Cartridge/Handle assembly
downward until Cartridge’s Bottom End Cap contacts the housing’s Tube
Sheet. The Cartridge’s Bottom End Cap will seal with the Stand-pipe
Coupling to prevent by-passing. A clockwise rotating motion will help to
position the Cartridge while engaging the Stand-pipe Coupling. Confirm all
Cartridge/Handle assemblies are fully installed with all Cartridge Bottom End
Caps contacting the housing’s Tube Sheet, see illustrations on page 17.
Stand-pipe
Cartridge/
Handle Assy
Lid Lifting
Wheel
Note:
Models HUR 3X, 5X & 8X (FL)
have a Lid/Davit Assy (swing
arm). The Lid Lifting Wheel
raises and lowers the Lid for
servicing.
DO NOT USE The Lid/Davit
Assy to raise the Lid while
swing bolts are engaged.
Model HUR 3X170FL
Davit Assy
Lid Assy
Inlet
Housing
O-ring
Upper Housing
Chamber Drain
Outlet