8-2. Current Position Value Setting Data (Master to Remote Station)
The master station can change the position data of VE-2CC/VM-2CC at arbitrary values by using the remote
register (RWw) and remote output (RY). (Current position value setting)
After setting, the remote station sends back the answer back signals by using remote inputs (RX). The master
station turns off the signal after checking the bit.
The information of setting position data is saved in non-volatile memory which is inside of the converter;
therefore, it is unnecessary that the current position value sets each time to turn ON the power
supply.
[Remote register RWw]
Device No.
Bit7
Bit6
Bit5
Bit4
Bit3
Bit2
Bit1
Bit0
RWw0(L)
PRD7
PED6
PRD5
PRD4
PRD3
PRD2
PRD1
PRD0
RWw0(H)
PRD15 PRD14 PRD13 PRD12 PRD11 PRD10 PRD9
PRD8
RWw1(L)
PRD23 PRD22 PRD21 PRD20 PRD19 PRD18 PRD17 PRD16
RWw1(H)
――
――
――
――
――
――
――
――
[Remote output RY]
Device No.
RY07
RY06
RY05
RY04
RY03
RY02
RY01
RY00
Signal name
――
――
――
――
――
――
――
ERROR
RESET
Device No.
RY0F
RY0E
RY0D
RY0C
RY0B
RY0A
RY09
RY08
Signal name
――
――
――
――
――
――
――
PRESET
[Remote input RX]
Device No.
RX0F
RX0E
RX0D
RX0C
RX0B
RX0A
RX09
RX08
Signal name
0
0
0
0
0
0
0
PRESET
ANSWER
[Signal explanation]
Signal name
Name
Contents
PRD0-23
Current position value
setting data
The position data can be changed to an arbitrary value by
switching “PRESET” signal to “1”. (binary code: PRD0-23)
(The data except the valid number of bits is fixed at 0.)*1
PRESET
Current position value
setting input signal
PRESET
ANSWER
Answer back
The value is 1 when the current position setting is operated
normally.
“RRESET ANSWER” signal is 0 when “RRESET” is changed to 0.
ERROR
RESET
Error clear
An error is cleared when switching this signal to “1” by following
method.
- Converter diagnosis data error (ME)
(The sensor error is automatically returned when error causes are
removed.)
*1: PRESET (RY08) signal should be turned OFF when the current position data and preset data are same
value.
The position data are changed when PRESET (RY08) signal is switched OFF to ON.
Note
In the state of having a sensor error, the current position setting is not available.
Summary of Contents for VE-2CC
Page 2: ......
Page 11: ...6 4 DIMENSIONS 4 1 Converter VE 2CC VM 2CC Units mm...
Page 12: ...7 4 2 ABSOCODER Sensor 1 VRE P028 Units mm...
Page 13: ...8 2 VRE P062 Units mm...
Page 14: ...9 Units mm...
Page 15: ...10 3 MRE 32SP062 MRE G SP062 Units mm...
Page 16: ...11 Units mm...
Page 17: ...12 4 3 Extension Sensor Cable 3P S 0102 L 3P RBT 0102 L 4P S 0102 L 4P RBT 0102 L Units mm...