NVC-
DN6118SD/IR User’s manual, ver. 1.0
All rights reserved © AAT Holding sp. z o.o.
21
CAMERA OSD MENU
NUMBER -
selects the tour number for editing or run.
PROGRAM
- enter the programing submenu. It displays screen as below. Using the joystick set
the desired field and change its value by pressing OPEN on the keyboard.
FUNCTION
- allows to choose PTZ function beetween:
P
- Preset,
T
- Pattern,
V
- Tour.
NO
- sets the number of the PTZ function.
V
- defines speed of switching to the preset (1 - the slowest, 9 - the fastest)
TIME
- defines time which camera stay in preset or the time after the pattern before show
next function.
Programmed tour could look like below:
Tour 1 consists : Preset1 (10sec.), Preset2 (10sec.), Pattern1 (5sec.)
RUN
- starts the selected tour.
DELETE
- deletes the selected tour from camera memory.
Program Tour1
Function
No.
V
Time
1
P
1
1
10
2
P
2
1
10
3
T
1
5
4
_
_
_
_
5
_
_
_
_
6
_
_
_
_
7
_
_
_
_
8
_
_
_
_
Press OPEN to Begin
Program Tour1
Function
No.
V
Time
1
→_
_
_
_
2
_
_
_
_
3
_
_
_
_
4
_
_
_
_
5
_
_
_
_
6
_
_
_
_
7
_
_
_
_
8
_
_
_
_
Press OPEN to Begin
http://www.e-camere.ro/camere-supraveghere/Novus/NVC-DN6118SD-IR