NVC-
DN6118SD/IR User’s manual, ver. 1.0
All rights reserved © AAT Holding sp. z o.o.
12
Except the hardware address (sets by DIP switch), camera allows to set software address.
Additional descritpion is in chapter 7.4 Menu System, Address function.
Selecting protocol parameters
Switches 1 and 2 are related with protocol selection. Table below depicts available switch
configurations:
Selecting transmission speed
Switches 3 and 4 are related with transmission speed. Table below depicts available switch
configurations:
Please pay attention to setting identical transmission parameters for controllers (keyboard, DVR, PC).
START-UP AND INITIAL CONFIGURATION
Transmission speed
Switch no
3
4
2400 bps
OFF
OFF
4800 bps
ON
OFF
9600 bps
OFF
ON
19200 bps
ON
ON
Protocol
Switch no
1
2
PELCO-D, PELCO-P
OFF
OFF
N-Control
OFF
ON
others
ON
OFF
http://www.e-camere.ro/camere-supraveghere/Novus/NVC-DN6118SD-IR