Development and manufacturing of non-
destructive testing units and system
Ultrasonic Flaw Detector NOVOTEST UD2301
16
B.
START
Coordinate of the beginning of the
selected gate. It can take values from 0
to the maximum value of scanning.
WIDTH
The width of the selected control gate
along the beam. It can take values from
0 to the maximum value of scanning.
The total value of the start and the width
of the gate can not exceed the value of
the maximum scanning.
LEVEL
The threshold level of the selected
control gate. Is given in % of the screen
height, can take values from 0 to 100%
of the screen height.
PARAM.1
Allows to select the measured value in
the first block. **
PARAM.1
Allows to select the measured value in
the first block. **
PARAM.1
Allows to select the measured value in
the first block. **
Functions GAIN
Setting of gain of received path from 0
to 115 dB at 0.1, 1 dB.
DGS
Turn on / off DGS
TVG
Turn on / off TVG
REJECT
Parameter allows to set the minimum
level of the signals displayed on the
screen.
PEAK
Turn on / off fixing the maximum
amplitude of the echo.
B-Scan
Turn on / off display of a scanning-type
B-scan.
AVG.
Number of echoes which are averaged