23
2.
WITH STOP DEVICE
2.1
Slide the rail in onto the stop device and hold it there until punching is completed. Setting the stop
device (see section "STOP DEVICE")
ATTENTION !
BEFORE ATTACHING AND REMOVING THE SYSTEM TOOLS OR
CARRYING OUT MAINTENANCE WORK, UNCOUPLE THE HYDRAULIC
UNIT OR DISCONNECT IT FROM THE MAINS!
Accessories
Punching with a template
Stop device, Order No. 7190
The stop device can be adjusted by 150 mm
in the X and Y axses.
The distance between the holes can be set
by using the scale or by using the fixed
distances on the templates. The arrangement of
the holes in the completed template conforms to
DIN 43673. The respective width of the intended
bar is inscribed on the template.
1.
Setting the stop device with the scale
1.1 Turn the thumb screws (56) anti-clock-
wise as far as they will go.
1.2 X-axis. Loosen the locking lever (55).
Set the stop rail (30) and tighten.
1.3 Y-axis. Loosen the thumb screw (57).
Set the slide (31) and tighten.
2.
Setting the stop device with a template
2.1
X-axis. Loosen the locking lever (55). Turn the thumb screw (56) clockwise as far as it will go and
hold. Set the stop rail (30) so that the stop bolt is positioned between the holes on the template (32).
Release the thumb screw (56) and slide the stop rail (30) until the stop bolt clicks into the next hole
on the template.
2.2
Y-axis. Loosen the thumb screw (57). Turn the thumb screw (56) clockwise as far as it will go and
hold. Set the slide (31) so that it is positioned between the holes on the template (32). Release the
thumb screw (56). Continue moving the slide (31) until it clicks into place in the next hole.