8.3 Performing the pressing operation
CAUTION!
Danger of crushing!
There is a risk that fingers and hands will be crushed.
Therefore:
– Keep body parts and foreign objects away from the press jaws during the pressing
operation.
– Do not hold the jaw levers with your hands during the pressing operation.
CAUTION!
Keep fingers away from the at-risk zone if no press jaw/adaptor jaw is
fitted. (Fig. 4)
Fingers risk being crushed.
Therefore:
– Do not operate the device without the jaws.
– Keep your fingers away from the at-risk zone.
Information!
The device will not start if the retaining pin (8) is incorrectly inserted. The green LED (2)
flashes.
Information!
Always comply with the operating instructions for the press tools!
1. Check whether the nominal width of the press fitting matches the nominal width of the press
jaw/press collar.
2. Comply with the system manufacturer's instructions when fitting the press jaw/press collar
(Fig. 8).
If using a press collar: Fit the adaptor jaw to the press collar as described in the press collar
manufacturer's instructions.
Information!
Make sure that the press jaw is fully closed when pressing is complete (Fig. 9).
Information!
Ensure there is no gap between the segments of the press collar when the
pressing operation is complete.
Information! (only ACO203 BT with wireless interface)
If the press device is switched off, briefly press the start button (1) to activate the
press device. Press the start button again to start the pressing operation.
3. To start the process, press the start button.
4. When pressing is complete:
•
If using a press collar: First detach the adaptor jaw from the press collar, then
•
Detach the press jaw/press collar from the press fitting (Fig. 10).