ACO203 / ACO203 BT / ECO203
18
EN
7 Brief description of the press device
7.1 Automatic press cycle (Fig. 1)
The device features an automatic press cycle. This ensures that the pressing operation is always
completed. The automatic press cycle is activated after approx. 1.5 seconds. After the automatic press
cycle has been triggered, the green LED (2) goes out and the pressing operation runs automatically.
The pressing operation can then only be stopped by pressing and holding release button (5). After the
pressing operation has been completed, the motor automatically switches off and the green LED (2)
lights up again.
If the start button (1) is released before the automatic press cycle begins, the piston in the press
device moves back to its starting position. The pressing operation will not have been completed. The
pressing operation must be triggered again.
7.2 Release button (Fig. 1)
The pressing operation can be stopped at any time by pressing and holding the release button (5).
The piston in the press device then returns to its starting position.
7.3 Pressing point lighting
When the start button (1) is pressed, the pressing point is lit by 2 LEDs (12). If the press device is out
of use for a longer period, the device and the LEDs switch off.
7.4 Wireless interface (only ACO203 BT) (Fig. 1)
The
ACO203 BT
device features a wireless interface if it shows the following characteristic:
•
Blue LED (10)
This wireless interface together with the NovoCheck app can be used to connect the
ACO203 BT
to a
mobile terminal device, such as a smartphone, tablet, etc. (Android, iOS; further information at
www.novopress.de). The following functions are available:
•
Reading the press device
•
Checking the press device
•
Making settings
•
Generating construction site reports.
To establish a connection, the press device must be operational and the NovoCheck app installed on
the terminal device.
The press device can now be connected with the NovoCheck app. (For more information, go to
www.novopress.de) When the connection to the wireless interface was established successfully, the
blue LED (10) lights up.
The blue LED (10) goes out if no connection has been established until the first pressing operation is
performed. A new attempt to establish the connection can only be made if the press device has been
switched off in the meantime. It may be necessary to pull the rechargeable battery for this.
If you do not wish to establish a connection, press the start button (1) once again and perform the
pressing operation.
7.5 Battery (ACO203 / ACO203 BT only)
Information!
The batteries are not charged at the factory.
Therefore:
– Charge the batteries before using for the first time.
Summary of Contents for ACO203
Page 2: ...ACO203 ACO203 BT ECO203 1 2 3 4 5 6 7...
Page 3: ...ACO203 ACO203 BT ECO203 8 9 10 11 12...
Page 4: ...ACO203 ACO203 BT ECO203...
Page 16: ...ACO203 ACO203 BT ECO203 12 DE...
Page 28: ...ACO203 ACO203 BT ECO203 24 EN...