SOFTENER
VALVE
FILTER
VALVE
SERVICE
2.0s
BRINE
2.0s
M. RATIO
5.714
BACKWASH
2.0s
RINSE
2.0s
REFILL
2.0s
VALVE TYPE
The valve must be designated as either SOFTENER or FILTER. This change will determine what options are available in the Factory
Settings.
METER RATIO
The meter ratio calibrates the pulse from the flow meter into gallons. This value is factory set and should not be changed.
DELAY SETTINGS
The delay settings are used to precisely stop the motor / piston in the correct position. This value is factory set and should not be
changed.
MASTER PROGRAMMING
MASTER OPTIONS (LEVEL III)
Press
SET
key
UP
and
DOWN
keys
Hold until you hear a beep (3 seconds).
Press
UP
or
DOWN
key
to advance each page.
Press
SET
key
to initiate a change.
Press
UP
or
DOWN
key
to change value.
Press
SET
key
to accept value. Press UP or DOWN key
to advance to next page.
CAUTION:
The values in this page are for illustration purpose and
can be changed by the factory without notice. Please
contact Customer Service to confirm proper settings.