18

19

Familiarize with Button Configuration:

3.

 Power and Program the Valve

Attach the Transformer cable to the valve and plug in the transformer to the 110V Power outlet. you will notice the two screens on right will alternate.  

6(77,1*6

83

'2:1

6(/(&7

TIME

08:27 AM

   

6(77,1*6

83

'2:1

6(/(&7

REMAIN

GAL 1060

1.

  Press 

MENU 

key 

 to advance to

 TIME OF DAY

TIME OF DAY

 will flash.  

6(77,1*6

83

'2:1

6(/(&7

TIME

08:27 AM

2.

  Press the 

UP

 or 

DOWN

 key 

  

 to adjust the 

TIME OF DAY

. Press & hold the 

UP

 or 

DOWN

 key 

  

 to quickly advance the hour and minutes. When desired time  

  is displayed press 

SET 

 

 to advance to the 

HARDNESS

 setting. 

HARDNESS

 will flash.  

6(77,1*6

83

'2:1

6(/(&7

HARDNESS

 020GPG

3.

  Press the 

UP 

or 

DOWN 

key 

  

 to adjust the 

HARDNESS

 (Min 1.Max 199). When desired hardness is displayed press 

SET 

 

 to advance to the 

PEOPLE

 setting (Min1/ 

 Max9). 

People will flash.  

6(77,1*6

83

'2:1

6(/(&7

PEOPLE

04 

4.

  When desired number of people is displayed press 

SELECT

 to complete pro-gramming. 

TIME

08:27 AM

KEYPAD

4

 

Add Salt to the brine tank/cabinet

4.

  Put 40 kgs of crystal water softener salt in the  

  brine tank. The unit will automatically fill the  

  water to the correct level when it regenerates.

BACKWASH

10 MIN

RINSE

10 MIN

BRINE

60 MIN

REFILL

11.1 MIN

1

1.

  Connect the transformer  

  to the valve.  Plug the  

  12-volt transformer into  

  a 120 VAC 60 Hz outlet.

2.

  Open the brine tank / 

  cabinet salt lid and  

  add water until there is  

  approximately 3” (75 mm)  

  of water in the tank. Do not  

  add salt to the brine tank at  

  this time. 

STARTUP INSTRUCTIONS

This function is to accept the values if changed and advance to the next page in 
the menu.

These buttons are used to increase or decrease the value of the settings while in 
the programming mode.

This function is to enter the basic set up information required at the time of 
installation.

Key Pad Configuration:

Manual Regeneration Using Keypad

Press “Setting Key” Once for Delayed Regenerations or Hold for 5 Seconds for Immediate Regeneration
Below is the sequence of Regeneration cycles

1.

 Backwash

2.

 Brine Draw and Slow Rinse

3.

 Rinse

4. 

Brine Refill

Summary of Contents for 165- 150

Page 1: ...edures for the continued proper operation of your unit These MUST be performed regularly for your warranty to remain valid 2 Read all instructions carefully before operation 3 Avoid pinched o rings du...

Page 2: ...TEPS 15 INSTALLING BRINE TANK 16 WATER SOFTENER INSTALLATION 17 CABINET WATER SOFTENER INSTALLATION 18 OPERATION STARTUP INSTRUCTIONS 19 MAINTENANCE INSTRUCTIONS 21 RES UP FEEDER INSTALLATION INSTRUCT...

Page 3: ...tified lubricant to all seals It is not uncommon for sediment precipitated iron or hardness to be present in water supplies Precipitated minerals or sediments can cause damage to the seals and piston...

Page 4: ...flow rate They have a demand initiated regeneration D I R feature that complies with specific performance specifica tions intended to minimize the amount of regenerant brine and water used in their o...

Page 5: ...oftener will not remove this type of iron 4 Bacterial Iron This type of iron is protected inside a bacteria cell Like the organic bound iron it is not removed bya water softener Water softeners remove...

Page 6: ...100C 26 500 22 000 14 000 10 0 2 4 10 x 35 1 00 13 0x22 5x44 0 300 104 SPECIFICATION Working Temperature 34 110 F 1 43 C Do not subject the unit to freezing temperatures Working Pressure 30 125 PSIG 1...

Page 7: ...1 x 34 7 18 9 x 18 9 x 65 6 270 0 122 2 BTR 145 Black 42 3 159 7 20 3 x 37 4 21 9 x 21 9 x 72 2 385 0 174 2 BTR 200 Grey 53 0 200 3 23 0 x 40 5 24 6 x 24 6 x 84 700 0 316 7 BTS 70 Black 19 0 71 8 13...

Page 8: ...8 VDOW JULG V VWHP VDOW WDQN ERG VDOW WDQN OLG EULQH ZHOO DQG EULQH YDOYH VDOW JULG V VWHP 75 O ODEHO BTR70 BTR145 BTR100 BTR200...

Page 9: ...els 75 10 15 20 you will expect the following 1 Control Valve 2 Tank 3 Parts Box 4 Owners Manual 5 Drain Hose Clamp Not included in some brands 6 Brine Tank Assembly UNPACKING INSPECTION OF TWIN TANK...

Page 10: ...th some models 5 Brine Tank Assembly Brine Tank Round or Square Brine Tank Tubing Brine Well Safety Float Brine Tank Lid Grid Round or Square Grid Legs 3 for Round and 4 for Square 5 Brine Tank Assemb...

Page 11: ...et with Valve attached 2 Parts Box 3 Drain Line and Hose Clamp Not Included with some models 18280 Upper Basket 2 Parts Box 60090003 2X 1 Straight Adapter 60010006 Bypass Tool 60010026 O Rings Attache...

Page 12: ...C 12 D 13 E 14 F 15 G 16 H 17 I 18 J 19 K 20 L 21 M 22 N 23 O 24 P 25 Q 26 R 27 S 28 T 29 U 30 V 31 Valve Serial CheckValveType andValve Serial Check to make sure the valve type is what you ordered T...

Page 13: ...them Tools Required for Installation NOTE We recommend installation only be completed by a competent installer or plumbing professional to insure this product is installed in accordance with local pl...

Page 14: ...he Upper Basket Unscrew the spill cap Carefully Slide the D Tube inside theValve and Screw theValve inside theTank such that the power cord doesnt get caught between the valve and the tank Place the m...

Page 15: ...inlet and outlet labels on the valve as shown here to determine the position of the equipment For DF Softener The inlet should be on the left hand side of the valve and out on the right hand side Fac...

Page 16: ...rine grid legs touches the bottom of the brine tank b Insert the brine well assembly inside the grid plate as well below d Take the brine tube and insert the nut and plastic sleeve as shown below e In...

Page 17: ...cal plumbing codes in regards to requirements for use of Check Valve or back flow prevention or vacuum breaker Connect Softener to the HousePlumbing Any solder joints near the valve must be done befor...

Page 18: ...ON Outlet Inlet NOTICE THERE ARE RAISED ARROWS ON THE BYPASS ASSEMBLY INDICATING DIRECTION OF WATER FLOW NOTE Check local plumbing codes in regards to requirements for use of Check Valve or back flow...

Page 19: ...to complete pro gramming TIME 08 27 AM KEYPAD 4 Add Salt to the brine tank cabinet 4 Put 40 kgs of crystal water softener salt in the brine tank The unit will automatically fill the water to the corr...

Page 20: ...turn the knob clockwise from the service position 9 00 to the 10 00 position Within a few seconds the an immediate regeneration will begin Using the knob you can manually advance to the next position...

Page 21: ...owing the unit to use up any remaining salt and then thoroughly cleaning out the brine tank Allow four hours to produce a brine solution then manually regenerate the softener Cleaning of your Brine Sa...

Page 22: ...filling no higher than the top of the brine well NOTE THEWATER LEVEL SHOULD BE BELOWTHE SALT LEVEL ALLTHETIME CAUTION Incorrect start up water above the salt level not enough salt in tank will both ef...

Page 23: ...depending on the inlet water quality and water usage The seals and spacer cartridge should be inspected cleaned or replaced every year depending on the inlet water quality and water usage Please refer...

Page 24: ...sert the wick making sure it touches the bottom of the bottle Insert the other end of the tube completely into the hole in the brine well cap Automatic feeding will start in a few hours 1 Install the...

Page 25: ...pply to conditioner a If the conditioner installation has a 3 valve bypass system first open the valve in the bypass line then close the valves at the conditioner inlet outlet b If the conditioner has...

Page 26: ...e the powerhead from the valve body assembly 6 Replace the powerhead by reverse following the steps in this section Piston Screw Washer 2 X Screws from Powerhead Powerhead Assembly Valve Body Assembly...

Page 27: ...e turned off and pressure relieved before Step 2 If there are TB L and TB H meter type options in PCB programming select TB H Ifthevalveprogramminghasno TB L and TB H options changethemeterratiotothe...

Page 28: ...ssembly grease it with silicone lubricant and put back in 5 Replace piston assembly followed by timer assembly 6 Replace the piston assembly and reverse following steps in this section Remove 2 X Scre...

Page 29: ...removing clips 3 Remove the coupling adapter from the bypass 4 Remove the meter and meter support from the bypass and replace 1 2 Meter Cable 3 REPLACE MOTOR Motor Screws 1 Remove back cover by removi...

Page 30: ...ll the drain line clip and remove the drain line elbow and washer 2 Clean replace drain line washer Drain Line Elbow REPLACING PCBS Remove PCBs by removing the screws shown in the picture REPLACE DRAI...

Page 31: ...0026 50010005 10010014 95600 100 9 x 48 25010034 25010036 25010035 50010005 95601 150 10 x 54 25010049 25010051 25010050 50010005 95606 200 12 x 52 25010058 25010060 25010059 50010005 95609 250 13 x 5...

Page 32: ...1 B20 60010100 Washer 3x13 1 B19 60010575 Screw ST4 2 12 Large Wafer 1 B18 60010661 Washer ST4 2 12 1 B17 60010662 Brine Gear 1 B16 60010663 Main Gear 1 B15 60010664 Bnt165 Drive Gear 1 B14 60010677...

Page 33: ...BODY 1 A7 60010657 DLFC 3 0GPM 1 A6 60010044 O RING 12 2 1 A5 60010229 QC DRAIN LINE ELBOW 1 A4 60010077 O RING 78 74 5 33 1 A3 60010080 O RING 25 3 55 1 A2 60010599 VALVE BOTTOM CONNECTOR 1 A1 600105...

Page 34: ...Shaft Inlet 1 21 60010740 Bypass Shaft Outlet 1 20 60095614 O ring 30 2 65 2 19 60010740 Shaft Seal 2 18 60010069 Plug Clip Red 2 17 60010740 Shaft Clip Red 2 16 60010209 Bypass Plug 2 15 60010044 O r...

Page 35: ...020019 TANK ASSY 935 NAT 1 25020020 TANK ASSY 1035 NAT 10 50010020 Distribution Assy 1035 1 9 18280 Top Cone 1 8 60095097 1 BypassValve Assy 1 7 165 ControlValve Grey 1 6 55010031 Softener Low Cover 1...

Page 36: ...be adjusted by a qualified person MASTER PROGRAMMING This function is to accept the values if changed and advance to the next page in the menu These buttons are used to increase or decrease the value...

Page 37: ...ETTINGS The delay settings are used to precisely stop the motor piston in the correct position This value is factory set and should not be changed MASTER PROGRAMMING MASTER OPTIONS LEVEL III Press SET...

Page 38: ...60 MIN BRINE 60 MIN RINSE 10 MIN RINSE 10 MIN RINSE 10 MIN REFILL 11 1 MIN REFILL 11 1 MIN REFILL 11 1 MIN REG TIME 12 00 AM BACKWASH 10 MIN RINSE 10 MIN SOFTENER MODE FILTER MODE CAUTION Thevaluesin...

Page 39: ...SOFTENER MODE FILTER MODE CAUTION Thevaluesinthispageareforillustrationpurposeand canbechangedbythefactorywithoutnotice Please contactCustomerServicetoconfirmpropersettings CALENDAR CLOCK METER IMMEDI...

Page 40: ...Toll Free 1 877 288 9888 Regina SK Cambridge ON Carmel IN Pottstown PA Phoenix AZ 54878 06 19...

Reviews: