NOVO 165- 150 Owner'S Manual Download Page 13

12

13

8QILOWHUHG:DWHU%\SDVV

/RRS&XW &DSSHG

*URXQG6WUDS5HTXLUHG%HFDXVH

RI%UHDNLQ&RQWLQXLW\

)LOWHUHG:DWHU/LQHLQ+RPH

Fig. 1.

BEFORE INSTALLATION

Make sure you have a copy of your most recent water test results. If your water has not been tested previously you can contact 

your supplier of this product to obtain a water sample bottle to be sent to one of our facilities for a free analysis. 

It is important 

that this product not be installed until you have this information

In all cases where metal pipe was originally used and is later interrupted by poly pipe or the Noryl bypass valve or by physical 

separation, an approved ground clamp with no less than #6 copper conductor must be used for continuity, to maintain proper 

metallic pipe bonding.

Inspecting and Handling Your 165 Softener* 

Inspect the equipment for any shipping damage. If damaged, notify the transportation company and request a damage 

inspection. Damage to cartons should also be noted.
Handle the filter unit with care. Damage can result if it is dropped or set on sharp, uneven projections on the floor.
Do not turn the filter unit upside down. 

To Insure this Product Functions Properly:

Your feed water line size to the unit must be a minimum of 3/4 inch with an operating pressure of no less than 30 

psi and no more than 125 psi

.

 

MECHANICAL: 

 

 Do not use petroleum based lubricants such as petroleum jelly, oils or hydrocarbon based lubricants.Use only 100% silicone 

lubricants (grease packet provided in parts kit). All plastic connections should be hand tightened only. Teflon tape may be used 

on connections that do not use an O-ring seal. Do not use pliers or pipe wrenches except where indicated by Nut shape (eg. pipe 

adapters) All plumbing must be completed according to local codes. Soldering connections should be done before connecting 

any pieces to the pipe as excessive heat can damage them. 

 

Tools Required for Installation:
NOTE: We recommend installation only be completed by a competent installer or 

plumbing professional to insure this product is installed in accordance with local 

plumbing codes.

Two adjustable wrenches

Additional tools may be required if modification to home plumbing is required.

Plastic inlet and outlet fittings are included with the filter.  To maintain full valve flow, 3/4” or 1” pipes to and from the  

 

filter fittings are recommended. You should maintain the same, or larger, pipe size as the water supply pipe, up to the filter  

 

inlet and outlet. 

Use copper, brass, or PEX pipe and fittings.

Some codes may also allow PVC plastic pipe.

ALWAYS install the included bypass valve, or 3 shut-off valves. Bypass valves let you turn off water to the filter for repairs if  

 

needed, but still  have water in the house pipes.

5/8” OD drain line is needed for the valve drain.  A 10’ length of hose is not included with some brands. 

 

NOTE

All government codes and 

regulations governing the 

installation of these devices 

must be observed.

NOTE

If a severe loss in water 

pressure is observed when 

the filter unit is initially 

placed in service, the filter 

tank may have been laid on 

its side during transit. If this 

occurs, backwash the filter 

to “reclassify” the media. 

*NOTE

 Due to transportation 

and climatic conditions all 

connections including the 

valve to the tank need to be 

checked at time of  

installation and tightened if 

necessary. 

NOTE

Check your local electrical 

code for the correct clamp 

and cable size.

CAUTION!

If the ground from the 

electrical panel or breaker 

box to the water meter or 

underground copper pipe 

is tied to the copper water 

lines and these lines are cut 

during installation of the No-

ryl bypass valve and/or poly 

pipe, an approved grounding 

strap must be used between 

the two lines that have been 

cut in order to maintain 

continuity. The length of the 

grounding strap will depend 

upon the number of units 

being installed and/or the 

amount of copper pipe being 

replaced with plastic pipe. 

See Fig. 1.

Summary of Contents for 165- 150

Page 1: ...edures for the continued proper operation of your unit These MUST be performed regularly for your warranty to remain valid 2 Read all instructions carefully before operation 3 Avoid pinched o rings du...

Page 2: ...TEPS 15 INSTALLING BRINE TANK 16 WATER SOFTENER INSTALLATION 17 CABINET WATER SOFTENER INSTALLATION 18 OPERATION STARTUP INSTRUCTIONS 19 MAINTENANCE INSTRUCTIONS 21 RES UP FEEDER INSTALLATION INSTRUCT...

Page 3: ...tified lubricant to all seals It is not uncommon for sediment precipitated iron or hardness to be present in water supplies Precipitated minerals or sediments can cause damage to the seals and piston...

Page 4: ...flow rate They have a demand initiated regeneration D I R feature that complies with specific performance specifica tions intended to minimize the amount of regenerant brine and water used in their o...

Page 5: ...oftener will not remove this type of iron 4 Bacterial Iron This type of iron is protected inside a bacteria cell Like the organic bound iron it is not removed bya water softener Water softeners remove...

Page 6: ...100C 26 500 22 000 14 000 10 0 2 4 10 x 35 1 00 13 0x22 5x44 0 300 104 SPECIFICATION Working Temperature 34 110 F 1 43 C Do not subject the unit to freezing temperatures Working Pressure 30 125 PSIG 1...

Page 7: ...1 x 34 7 18 9 x 18 9 x 65 6 270 0 122 2 BTR 145 Black 42 3 159 7 20 3 x 37 4 21 9 x 21 9 x 72 2 385 0 174 2 BTR 200 Grey 53 0 200 3 23 0 x 40 5 24 6 x 24 6 x 84 700 0 316 7 BTS 70 Black 19 0 71 8 13...

Page 8: ...8 VDOW JULG V VWHP VDOW WDQN ERG VDOW WDQN OLG EULQH ZHOO DQG EULQH YDOYH VDOW JULG V VWHP 75 O ODEHO BTR70 BTR145 BTR100 BTR200...

Page 9: ...els 75 10 15 20 you will expect the following 1 Control Valve 2 Tank 3 Parts Box 4 Owners Manual 5 Drain Hose Clamp Not included in some brands 6 Brine Tank Assembly UNPACKING INSPECTION OF TWIN TANK...

Page 10: ...th some models 5 Brine Tank Assembly Brine Tank Round or Square Brine Tank Tubing Brine Well Safety Float Brine Tank Lid Grid Round or Square Grid Legs 3 for Round and 4 for Square 5 Brine Tank Assemb...

Page 11: ...et with Valve attached 2 Parts Box 3 Drain Line and Hose Clamp Not Included with some models 18280 Upper Basket 2 Parts Box 60090003 2X 1 Straight Adapter 60010006 Bypass Tool 60010026 O Rings Attache...

Page 12: ...C 12 D 13 E 14 F 15 G 16 H 17 I 18 J 19 K 20 L 21 M 22 N 23 O 24 P 25 Q 26 R 27 S 28 T 29 U 30 V 31 Valve Serial CheckValveType andValve Serial Check to make sure the valve type is what you ordered T...

Page 13: ...them Tools Required for Installation NOTE We recommend installation only be completed by a competent installer or plumbing professional to insure this product is installed in accordance with local pl...

Page 14: ...he Upper Basket Unscrew the spill cap Carefully Slide the D Tube inside theValve and Screw theValve inside theTank such that the power cord doesnt get caught between the valve and the tank Place the m...

Page 15: ...inlet and outlet labels on the valve as shown here to determine the position of the equipment For DF Softener The inlet should be on the left hand side of the valve and out on the right hand side Fac...

Page 16: ...rine grid legs touches the bottom of the brine tank b Insert the brine well assembly inside the grid plate as well below d Take the brine tube and insert the nut and plastic sleeve as shown below e In...

Page 17: ...cal plumbing codes in regards to requirements for use of Check Valve or back flow prevention or vacuum breaker Connect Softener to the HousePlumbing Any solder joints near the valve must be done befor...

Page 18: ...ON Outlet Inlet NOTICE THERE ARE RAISED ARROWS ON THE BYPASS ASSEMBLY INDICATING DIRECTION OF WATER FLOW NOTE Check local plumbing codes in regards to requirements for use of Check Valve or back flow...

Page 19: ...to complete pro gramming TIME 08 27 AM KEYPAD 4 Add Salt to the brine tank cabinet 4 Put 40 kgs of crystal water softener salt in the brine tank The unit will automatically fill the water to the corr...

Page 20: ...turn the knob clockwise from the service position 9 00 to the 10 00 position Within a few seconds the an immediate regeneration will begin Using the knob you can manually advance to the next position...

Page 21: ...owing the unit to use up any remaining salt and then thoroughly cleaning out the brine tank Allow four hours to produce a brine solution then manually regenerate the softener Cleaning of your Brine Sa...

Page 22: ...filling no higher than the top of the brine well NOTE THEWATER LEVEL SHOULD BE BELOWTHE SALT LEVEL ALLTHETIME CAUTION Incorrect start up water above the salt level not enough salt in tank will both ef...

Page 23: ...depending on the inlet water quality and water usage The seals and spacer cartridge should be inspected cleaned or replaced every year depending on the inlet water quality and water usage Please refer...

Page 24: ...sert the wick making sure it touches the bottom of the bottle Insert the other end of the tube completely into the hole in the brine well cap Automatic feeding will start in a few hours 1 Install the...

Page 25: ...pply to conditioner a If the conditioner installation has a 3 valve bypass system first open the valve in the bypass line then close the valves at the conditioner inlet outlet b If the conditioner has...

Page 26: ...e the powerhead from the valve body assembly 6 Replace the powerhead by reverse following the steps in this section Piston Screw Washer 2 X Screws from Powerhead Powerhead Assembly Valve Body Assembly...

Page 27: ...e turned off and pressure relieved before Step 2 If there are TB L and TB H meter type options in PCB programming select TB H Ifthevalveprogramminghasno TB L and TB H options changethemeterratiotothe...

Page 28: ...ssembly grease it with silicone lubricant and put back in 5 Replace piston assembly followed by timer assembly 6 Replace the piston assembly and reverse following steps in this section Remove 2 X Scre...

Page 29: ...removing clips 3 Remove the coupling adapter from the bypass 4 Remove the meter and meter support from the bypass and replace 1 2 Meter Cable 3 REPLACE MOTOR Motor Screws 1 Remove back cover by removi...

Page 30: ...ll the drain line clip and remove the drain line elbow and washer 2 Clean replace drain line washer Drain Line Elbow REPLACING PCBS Remove PCBs by removing the screws shown in the picture REPLACE DRAI...

Page 31: ...0026 50010005 10010014 95600 100 9 x 48 25010034 25010036 25010035 50010005 95601 150 10 x 54 25010049 25010051 25010050 50010005 95606 200 12 x 52 25010058 25010060 25010059 50010005 95609 250 13 x 5...

Page 32: ...1 B20 60010100 Washer 3x13 1 B19 60010575 Screw ST4 2 12 Large Wafer 1 B18 60010661 Washer ST4 2 12 1 B17 60010662 Brine Gear 1 B16 60010663 Main Gear 1 B15 60010664 Bnt165 Drive Gear 1 B14 60010677...

Page 33: ...BODY 1 A7 60010657 DLFC 3 0GPM 1 A6 60010044 O RING 12 2 1 A5 60010229 QC DRAIN LINE ELBOW 1 A4 60010077 O RING 78 74 5 33 1 A3 60010080 O RING 25 3 55 1 A2 60010599 VALVE BOTTOM CONNECTOR 1 A1 600105...

Page 34: ...Shaft Inlet 1 21 60010740 Bypass Shaft Outlet 1 20 60095614 O ring 30 2 65 2 19 60010740 Shaft Seal 2 18 60010069 Plug Clip Red 2 17 60010740 Shaft Clip Red 2 16 60010209 Bypass Plug 2 15 60010044 O r...

Page 35: ...020019 TANK ASSY 935 NAT 1 25020020 TANK ASSY 1035 NAT 10 50010020 Distribution Assy 1035 1 9 18280 Top Cone 1 8 60095097 1 BypassValve Assy 1 7 165 ControlValve Grey 1 6 55010031 Softener Low Cover 1...

Page 36: ...be adjusted by a qualified person MASTER PROGRAMMING This function is to accept the values if changed and advance to the next page in the menu These buttons are used to increase or decrease the value...

Page 37: ...ETTINGS The delay settings are used to precisely stop the motor piston in the correct position This value is factory set and should not be changed MASTER PROGRAMMING MASTER OPTIONS LEVEL III Press SET...

Page 38: ...60 MIN BRINE 60 MIN RINSE 10 MIN RINSE 10 MIN RINSE 10 MIN REFILL 11 1 MIN REFILL 11 1 MIN REFILL 11 1 MIN REG TIME 12 00 AM BACKWASH 10 MIN RINSE 10 MIN SOFTENER MODE FILTER MODE CAUTION Thevaluesin...

Page 39: ...SOFTENER MODE FILTER MODE CAUTION Thevaluesinthispageareforillustrationpurposeand canbechangedbythefactorywithoutnotice Please contactCustomerServicetoconfirmpropersettings CALENDAR CLOCK METER IMMEDI...

Page 40: ...Toll Free 1 877 288 9888 Regina SK Cambridge ON Carmel IN Pottstown PA Phoenix AZ 54878 06 19...

Reviews: