Installation Manual
ALS 30x
02/2016 | 00
40
Installation and Deinstallation
Adjusting the Novexx sensor
Press the button [65A] for 2 s, until the status LEDs
[65B] light permanently.
–
Notice
: Don´t press the button for longer than 5 s,
otherwise you risk to switch between NPN/PNP, see
chapter
Switching the Novexx sensor - PNP/NPN
– After releasing the button, a teaching „time window“
opens for 2-8 s. During this period, the status LEDs
are flashing fast [66].
While the LEDs are flashing, move as many label
gaps as possible (at least 2) through the sensor fork.
– The movement direction of the label gap is irrele-
vant, that is the same label gap may be moved back
and forth several times.
– The label gaps have to be moved
manually
,
not
by
pressing the
button.
– If the label gaps were detected successfully, the sta-
tus LEDs are flashing 2x [67].
– If the label gaps were not detected ideal, the status
LEDs are flashing 4x.
Repeat the procedure, if the label gaps were not de-
tected ideal.
[65] Starting the autoteaching.
[66] Autoteaching is indicated by flashing LEDs.
[67] Sensor is successfully set = flashing 2x.
m
in
. 2 s
A
B
2-8 s
mi
n. 2x