5.3.1
User interface
Select:
Settings
→ “
Installation settings
” → “user
Interface
”
Accuracy tolerances (Green level)
•
Height difference:
Surface
,
Point
and
line
dZ and
DTM+Line dSl "Green level" tolerance
•
Sideway difference: DTM+Line dSl, Line dS and
Point dS/dL "Green level" tolerances
Profile view maximum zoom vs. bucket width (selecting
100% → the bucket fills whole screen)
Profile viewer height → select suitable height for the profile
view (60px...350px, 200px is the default)
Point autosnap settings: Mode
•
3D autosnap: Closest object in autosnap mode is calculated in XYZ
•
2D autosnap: Closest object in autosnap mode is calculated in XY
•
Active point switch threshold: How many percent closer a new object needs to be before
autosnap function is changing to nearest object (0% is the default)
Installation settings
→
File import
→
Drawing distance
Setting the
Drawing distance
(10 metres to 10 kilometres) affects how far from the measurement
point the map is drawn. Smaller value gives better performance (map will be updated faster on the
display).
5.4 Operations
Operations
•
Create reference line
(See section 5.4.1)
•
Accuracy control:
Optional feature, contact support for detailed information.
◦
(Compare measurement point to the known reference point. Can be activated by a
service personnel.)
•
Drilling plan creator
: (See section 5.4.2)
User Manual. Xsite PRO SPI 14.2 Page 53 / 77
Fig. 65: User interface
Summary of Contents for XSITE PRO SPI 14.2
Page 1: ...XSITE PRO SPI 14 2 USER MANUAL Version 1 14 2 46 October 2018...
Page 33: ...Fig 36 Tilt bucket calibration User Manual Xsite PRO SPI 14 2 Page 30 77...
Page 76: ...User Manual Xsite PRO SPI 14 2 Page 73 77...
Page 77: ...User Manual Xsite PRO SPI 14 2 Page 74 77...