6.3 Tilting bucket accuracy test
When using the tilt function, test the accuracy of the bucket edges.
1. Straighten the tilt rotator (if the machine is equipped with one)
2. Switch the measuring point to “Center”
3. Set the bucket blade on a horizontal level and move the centre of the bucket to the
reference point. Zero the measurement readings
4. Tilt the bucket and put the left corner on the reference point
5. Height and lengthwise distance readings should be as close to “0.00” as possible in every
position
6. Repeat this accuracy test with the other corner of the bucket
7. If the accuracy is off by more than ±2 cm recalibrate the bucket. See section 3.10.2 “Tilt
bucket calibration”.
Tilt bucket accuracy test
User Manual. Xsite PRO SPI 14.2 Page 64 / 77