7. MAINTENANCE

1. In order to ensure the good performance of the product, please store it in a dark and dry place when not in use, do not 

press it heavily.

2. The device is a precision detector, do not use strong vibration.

3. Do not immerse electronic equipment.

 www.novacom-vacuum.com

6. COMMUNICATION PROTOCOL

Baud rate: 10K

Frame format: standard pin

Frame type: data frame

ID(Address)= 1, 2, 3,… (settable)

Default Ack= 1 Interid= 0

Frame id= (CanIdData->Address<<4) | (CanIdData->Ack<<3) | (CanIdData->Interid &0x07);

For example:

ID (Address) = 1 frame id = 00 00 00 18

ID (address) = 2 frames id = 00 00 00 28

[8-bit data description (hexadecimal)]

10(default) 00 (working state) 00 (working type) 01 (working distance) X0 00 00 00 (measured data)

Working state description: 00 normal 02 max min alarm

Working type description: 00 default

Description of working distance: 01 - > 25mm 02 - > 50mm

Description of measurement data: X0 00 00 00 (X=0 negative static X=1 positive static)

[parameter setting]

Modification ID: 10 A0 01 (id= 01 02 03……….) 00 00 00 00 00

Modify test distance: 10 A1 01 (01 02) 00 00 00 00 00

Modify the positive and negative alarm values: 10 A3 27 10

(positive static telegraph alarm value 10000v) 27 10 (negative static alarm value 10000v) 00 00

[electrostatic voltage reading]

Read electrostatic voltage value: 10 B4 00 00 00 00 00 00

6.1. DESCRIPTION OF THE CAN PROTOCOL

Summary of Contents for CDCS ION

Page 1: ...ELECTROSTATIC FIELD METER CDCS ION www novacom vacuum com INSTRUCTIONS...

Page 2: ...use original parts Turn off power after use and take out the battery if not used during an extended period of time Please keep this manual for reference at any time 1 Overview of the static field mete...

Page 3: ...fectively detect the static electricity carried by objects such as plastics chemical fiber fur or human body This static field meter is simple to use and easy to carry It is an indispensable tool in t...

Page 4: ...display 0 20kV displayed with 2 decimal places unit kV 20 60 kV displayed with 1 decimal place unit kV Ion balance mode display 0 200V unit V Sound alarm When power is on it will ring once During aut...

Page 5: ...value the green light of the network port will flash 3 Use the external power supply and press the power button of the measurer When the measurer is on the yellow light of the network port is always o...

Page 6: ...ower button to turn on the measurer the status indicator light is on the green light indicator is on the sound alarm rang once and the content is displayed on the screen Press the HOLD key button brie...

Page 7: ...turn off automatically At that point the battery needs to be replaced before the measurer can work properly again Battery replacement remove the battery cover at the back of the static field meter rem...

Page 8: ...00 00 00 28 8 bit data description hexadecimal 10 default 00 working state 00 working type 01 working distance X0 00 00 00 measured data Working state description 00 normal 02 max min alarm Working ty...