10
Document 51996 AFP-300/400 NION Installation Rev. A1 03/04/03
Figure 1-2: AFP-300/400 NION Board Layout
3V Lithium
3V Lithium
3V Lithium
3V Lithium
3V Lithium
Battery
Battery
Battery
Battery
Battery
J1 Header for Echelon
J1 Header for Echelon
J1 Header for Echelon
J1 Header for Echelon
J1 Header for Echelon
Network T
Network T
Network T
Network T
Network Transceiver
ransceiver
ransceiver
ransceiver
ransceiver
Application PLCC
Application PLCC
Application PLCC
Application PLCC
Application PLCC
SW2 Network
SW2 Network
SW2 Network
SW2 Network
SW2 Network
Binding Button
Binding Button
Binding Button
Binding Button
Binding Button
SW1 Reset
SW1 Reset
SW1 Reset
SW1 Reset
SW1 Reset
Button
Button
Button
Button
Button
Network Communication
Network Communication
Network Communication
Network Communication
Network Communication
PLCC
PLCC
PLCC
PLCC
PLCC
SMX T
SMX T
SMX T
SMX T
SMX Transceiver
ransceiver
ransceiver
ransceiver
ransceiver
Standoff Mounting
Standoff Mounting
Standoff Mounting
Standoff Mounting
Standoff Mounting
Holes
Holes
Holes
Holes
Holes
Chassis
Chassis
Chassis
Chassis
Chassis
Ground
Ground
Ground
Ground
Ground
{
Diagnostic LEDS
Diagnostic LEDS
Diagnostic LEDS
Diagnostic LEDS
Diagnostic LEDS
R72 Cut T
R72 Cut T
R72 Cut T
R72 Cut T
R72 Cut To Disable
o Disable
o Disable
o Disable
o Disable
Ground Fault Detection
Ground Fault Detection
Ground Fault Detection
Ground Fault Detection
Ground Fault Detection
GND +24VDC
PPPPPower Input (TB5)
ower Input (TB5)
ower Input (TB5)
ower Input (TB5)
ower Input (TB5)
P2 Serial Interface B
P2 Serial Interface B
P2 Serial Interface B
P2 Serial Interface B
P2 Serial Interface B
NUP P
NUP P
NUP P
NUP P
NUP Port (EIA
ort (EIA
ort (EIA
ort (EIA
ort (EIA-232)
-232)
-232)
-232)
-232)
TB6-Relay Output
TB6-Relay Output
TB6-Relay Output
TB6-Relay Output
TB6-Relay Output
U24
U24
U24
U24
U24
BT1
BT1
BT1
BT1
BT1
U6
U6
U6
U6
U6
TB1-Serial Interface A
TB1-Serial Interface A
TB1-Serial Interface A
TB1-Serial Interface A
TB1-Serial Interface A
P1 Serial Interface A
P1 Serial Interface A
P1 Serial Interface A
P1 Serial Interface A
P1 Serial Interface A
NUP P
NUP P
NUP P
NUP P
NUP Port (EIA
ort (EIA
ort (EIA
ort (EIA
ort (EIA-232)
-232)
-232)
-232)
-232)
NOTES: The AFP-300/400 NION is only compatible with AFP-300/400 firmware
version 3.6 or later.
It is recommended that the installer conform to local code requirements when installing
all wiring. All power connections must be non-resettable. Refer to the current Notifier
catalog for specific part numbers and ordering information for each NION.
To avoid damage to hardware, always remove power from the NION before making
any changes to switch settings and removing or installing option modules, SMX network
modules and software upgrade chips.
Always observe ESD protection procedures.
J1
J1
J1
J1
J1
Technical Manuals Online! - http://www.tech-man.com
firealarmresources.com