![Northern Telecom Meridian SL-1 Installation And Testing Instructions Download Page 53](http://html1.mh-extra.com/html/northern-telecom/meridian-sl-1/meridian-sl-1_installation-and-testing-instructions_1708625053.webp)
I n s t a l l a t i o n 3 - 4 7
2-Mb/s Remote Peripheral Equipment Appendix 1 to 553-2741-200
C h a r t 3 - 6 ( c o n t i n u e d )
Alarm and transfer wiring (P10) installation
S t e p
P r o c e d u r e
5
Terminate and designate cable 2 (if provided) at the cross-
connect terminal as follows (Figure 2-10):
• Terminate the black wire associated with the red wire and
designate as REM A.
• Terminate the black wire associated with the white wire and
designate as REM B.
• Terminate the red wire and designate as MJ.
• Store the remaining white wire (not used) and the braided wire
(connected only in the cabinet).
6
Connect cable 1 (if provided) to the terminals on TB2 at the rear
of the QUX19 unit in the cabinet as follows:
• red wire to terminal 5 (AUX) on TB2
• white wire to terminal 4
• black wire associated with the white wire to terminal 8 (XPE)
• black wire associated with the red wire to terminal 9 (XCE)
• braided bare wire to terminal 4
7
Connect cable 2 (if provided to terminals on TB2 at the rear of
the QUX19 as follows:
• black wire associated with the red wire to terminal 6 (REMA)
• black wire associated with the white wire to terminal 7 (REMB)
• red wire to terminal 10 (MJ)
• braided bare wire to terminal 4
• store the white wire (not used)
8
If required, reinstall cabinet cover