52 QSIO circuit pack
297-1001-536 Standard 01.03 August 1996
Table 6–1
QSIO circuit pack (A6 and B6) options – part number: NT6M60AA
(continued)
Device type
(number)
Setting
Factory On–site
Function
Position/setting
DIP
Switch
(S1)
Position
0
1
2
3
4
=
5
6
7
8
9
Address
A
B
C
D
E
F
Select the logical
address of the SIO
circuits.
A
Must be
the same
as the
factory
setting.
Note: Baud rate selection for the four DPP channels is made at the four rotary switches (S4, S5, S6,
and S7) on the front of the circuit pack. The baud rate selected can be set for synchronous or
asynchronous operation at S2 and S3. The chart shows conversion for asynchronous to
synchronous baud rates and rotary switch position for the applicable selection.
Switch
position
Asynch
rate
Synch
rate
Switch
position
Asynch
rate
Synch
rate
0
50
800
8
1800
N/A
1
75
1200
9
2000
N/A
2
110
1760
A
2400
N/A
3
134.5
2152
B
3600
N/A
4
150
2400
C
4800
N/A
5
300
4800
D
7200
N/A
6
600
9600
E
9600
N/A
7
1200
19200
6
F
19200
6
N/A
Rotary
Switch
(S4)
0
1
2
3
4
5
6
7
50
75/1200
110
134.5
150/2400
300/4800
600/9600
1200
8
9
A
B
C
D
E
F
1800
2000
2400
3600
4800
7200
9600
19200
6
BX.25 Polling Link
(Synchronous channel;
2400 baud) Channel A
baud rate select. (Odd
numbers appear as
dashes on the face of
the rotary switch.)
5
May be 4,
(4800
5, or 6, de–
baud)
pending
on the
polling
speed.
(This switch is inac-
tive for DPP systems
with 56K polling.)
(continued)