OM-NI 2/20
16
Troubleshooting
FAULT
REMEDY
Compressor Overload
Compressor amperage high. Check raw water circuit for restriction.
Auger Overload
Auger amperage high. Check ice delivery hose for blockage.
Raw Water Pump Overload Pump amperage high. Check raw water circuit for restriction.
Discharge Pressure
Discharge pressure high. Check raw water circuit for restriction.
Suction Pressure
Suction pressure low. Check ice delivery hose for blockage.
INDICATIONS DESCRIPTION
Compressor
Compressor running
Auger
Auger running
Raw Water Pump
Pump running
Water Valve Solenoid
Water valve solenoid energized
Discharge Pressure OK
High pressure switch closed
Suction Pressure OK
Suction pressure switch closed
Water Level Low
Water reservoir filling with water. If indication stays on for more than a
minute check fresh water feed.
Start/Stop/Reset
Indicates status of switch
Bin Full
On when bin is full, off when bin level drops