
OM-NI 2/20
9
ICE CONNECTION
FOR DELIVERY HOSE
ELECTRICAL BOX
D
C
B
A
B
C
D
1
2
3
4
5
6
7
8
8
7
6
5
4
3
2
1
E
F
E
F
SHEET 1 OF 1
MCE
UNLESS OTHERWISE SPECIFIED:
SCALE:
REV
DWG. NO.
C
SIZE
NAME
DATE
COMMENTS:
Q.A.
MFG APPR.
ENG APPR.
CHECKED
DRAWN
FINISH
MATERIAL
INTERPRET GEOMETRIC
TOLERANCING PER:
DIMENSIONS ARE IN INCHES
TOLERANCES:
FRACTIONAL
ANGULAR: MACH BEND
TWO PLACE DECIMAL
THREE PLACE DECIMAL
APPLICATION
USED ON
NEXT ASSY
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THIS
DRAWING IS THE SOLE PROPERTY OF
TECHNICOLD. ANY REPRODUCTION IN
PART OR AS A WHOLE WITHOUT THE
WRITTEN PERMISSION OF
TECHNICOLD IS PROHIBITED.
A
DO NOT SCALE DRAWING
1419 W NEWPORT CENTER DRIVE
DEERFIELD BEACH, FL 33442
1-800-843-6140
TEL: (954)-421-1717
FAX:(954)-421-1712
M
ICE CONNECTION
FOR DELIVERY HOSE
ELECTRICAL BOX
D
C
B
A
B
C
D
1
2
3
4
5
6
7
8
8
7
6
5
4
3
2
1
E
F
E
F
SHEET 1 OF 1
MCE
UNLESS OTHERWISE SPECIFIED:
SCALE:
REV
DWG. NO.
C
SIZE
NAME
DATE
COMMENTS:
Q.A.
MFG APPR.
ENG APPR.
CHECKED
DRAWN
FINISH
MATERIAL
INTERPRET GEOMETRIC
TOLERANCING PER:
DIMENSIONS ARE IN INCHES
TOLERANCES:
FRACTIONAL
ANGULAR: MACH BEND
TWO PLACE DECIMAL
THREE PLACE DECIMAL
APPLICATION
USED ON
NEXT ASSY
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THIS
DRAWING IS THE SOLE PROPERTY OF
TECHNICOLD. ANY REPRODUCTION IN
PART OR AS A WHOLE WITHOUT THE
WRITTEN PERMISSION OF
TECHNICOLD IS PROHIBITED.
A
DO NOT SCALE DRAWING
1419 W NEWPORT CENTER DRIVE
DEERFIELD BEACH, FL 33442
1-800-843-6140
TEL: (954)-421-1717
FAX:(954)-421-1712
M
When handling the unit use gloves and any other safety
equipment deemed necessary to prevent bodily injury.
Protect surfaces to prevent damage when transporting
equipment onboard and during installation.
The frame on for unit is capable of supporting the weight
of the unit. To aid installation and carrying the unit, the
top cover can be removed and the unit carried by the top
of the frame. To remove the top cover, use a flat-head
screwdriver to turn the latches 180 degrees counter-clock-
wise.
Check that you have all the parts needed for the installa-
tion.
Mount the unit on a flat surface to prevent vibration.
Locate the unit as far aft as possible and low in the boat.
Do not mount it further forward than amidships
The unit has two drains. For best drainage mount the unit
so that the drains are fore & aft.
Connect both drain lines on an incline downward to a
sump pump. If you decide to connect only one drain con-
nection, cap the other.
There are four mounting clips provided to secure to
machine to its mounting surface. (Figure 3) Install the
clips once the installation is complete and the panels are
in place. Use all four clips to secure the unit properly. For
the most secure application, mount the clips opposite each
other. This can be two on either side or one on each of the
four sides.
Installation
You only need to remove two panels for installation, the
top cover and the left-hand side panel.
Removing the top cover provides access to the electri-
cal box and for connection of the ice delivery hose. To
remove the top cover turn the captive locks 180 degrees
counter-clockwise.
Fig. 4: Electrical box and
ice connection
Fig. 3: Ice machine showing location of mounts (left), mount details (right)